408 results
Omron / 3G2
This programming console operates effectively at an input frequency of 50 to 60 Hertz and weighs 5.8 pounds (2.63 kilograms). It can function within ambient temperatures from 0 to 55°C and can be stored at temperatures ranging from -20 to 65°C. The humidity tolerance is between 35 and 85% relative h
Omron / 3G2
This I/O terminal cover is not a standard type, but rather a special model intended for terminal block applications. It operates effectively within a temperature range of 0°C to 55°C and maintains functionality in humidity levels from 10% to 90%, provided there's no condensation. Compliance with RoH
Omron / 3G2
This remote I/O slave unit operates in environments rated IEC IP-30 and can withstand temperatures ranging from 0°C to 55°C. It employs a time-shared multiplex cyclic communication method over a 2-core optical fiber connection, with a maximum transmission distance of 6.4 kilometers. The configuratio
Omron / 3G2
This transistor output unit has a maximum switching capacity of 1 amp at voltages between 12 to 48 VDC, and it can accommodate up to 5 amps per unit. With dimensions that conform to an A-shape design, it weighs no more than 500 grams, making it suitable for space-constrained applications.
Omron / 3G2
With the capability to accept up to four analog inputs, this module is specifically made for environments needing accurate voltage measurements. It measures 34.5 mm in width, 250 mm in height, and 113 mm in depth. The external connections are made through a non-removable 17-pin terminal block, ensur
Omron / 3G2
This CPU module features a total instruction set of 71, including 12 basic and 59 special instructions. It boasts a memory capacity of 24k words and operates efficiently with execution times ranging from 3 to 8 microseconds for basic tasks and 22 to 504 microseconds for special ones. Additionally, t
Omron / 3G2
This converter functions effectively at an input frequency of 50 Hz. It delivers an output voltage spanning from 0 to 460 V AC, with a maximum output current of 11 A. The output power rating reaches 8.4 KVA, allowing for significant load handling capabilities. Designed with V/f control, it operates
Omron / 3G2
This inverter drive operates across a frequency range of 0.1 to 400 Hz and employs sinusoidal PWM control for a smooth motor operation. It features a fan-cooled system, ensuring efficient heat management, weighing approximately 2.5 kg. This unit supports an overload capacity of up to 150% for 60 sec
Omron / 3G2
This output unit consists of 16 output points with independent common functionality. It operates effectively within a voltage range of 12 to 24 VDC. The ON response time is capped at 0.2 ms, while the OFF response time does not exceed 0.3 ms. It does not produce leakage current and maintains a resid