404 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed with two poles, this circuit breaker has a frame type classified as F Frame. It supports operation within a frequency range of 50 to 60 Hz. Interrupt ratings are notable, with 18 KAIC at 240 VAC and 14 KAIC at 480 VAC, making it suitable for a variety of power distribution applications.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for versatility, this breaker features three poles and provides reverse feed protection functions. It connects through feed-thru and includes terminal lugs for load-side connections and a busbar for line-side connections. It operates efficiently at frequencies ranging from 50 to 60 Hertz, c
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for three-pole configurations, the EDH3100 features a thermal magnetic trip unit that supports both long-time and instantaneous protection functions. It utilizes lugs for load side connections and accommodates busbar connections on the line side. The device has an impressive interrupting ra
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is equipped with a fixed thermal and fixed magnetic trip unit. It features a connection type of bolt-on and can handle a DC voltage of 250 V. With an interrupt rating of 100 kA at 240 V and 65 kA at 480 V, it provides substantial protection against overcurrent conditions. The un
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The trip unit features three poles and includes long-time and instantaneous tripping functions (LI). With a frequency rating between 50 and 60 Hertz, this thermal magnetic trip unit is compliant with UL standards and is compatible with multiple circuit breaker frames, including CKD and KD.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates at a maximum AC voltage of 600 VAC with a feed-thru connection type. It features a K-frame design and is capable of providing magnetic-only protection. Additionally, it has a 35 kA AIC rating at 480 V, ensuring protection against fault currents. It is also suitable for
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This accessory is designed for 3-pole installations and utilizes a feed-thru connection method. It provides magnetic-only protection with instantaneous functions, ensuring swift response times during fault conditions. Rated for operation in humid environments up to 80% non-condensing, it can be inst
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
With support for operation at voltages of 480Y/277 VAC and 125/250 VDC, the GHB2060 is well-suited for various electrical systems. The unit has a fixed thermal and magnetic trip type and operates effectively within a frequency range of 50 to 60 Hertz. Its interrupt rating is 14 kAIC at 480Y/277 VAC
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates with a rated current of 15 A, suitable for various applications. It has an interrupting capacity of 14 kA at 480 V and 18 kA at 240 V. Supporting frequencies of 50 to 60 Hz, this breaker is specifically designed with load side terminals.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit features three poles and operates under a thermal-magnetic trip mechanism, known as the TI85 type. It supports installation at altitudes up to 1000 meters above sea level and is designed to function within specific temperature limits of 0°C to 40°C for both operation and storage.