86 results
Eaton Cutler-Hammer / PLCs / Power Defense
Featuring two poles, this breaker is designed for a 1-phase system and includes feed-thru connection types. It operates at a voltage of 600 VAC and has an interrupt rating of 25 kAIC at 480 VAC. The trip functions include long time and instantaneous trip capabilities, managed through a thermal magne
Eaton Cutler-Hammer / PLCs / Power Defense
This shunt trip accessory supports Frame J-K sizes and features a pigtail connection measuring 0.75 meters. It maintains functionality within a 0°C to 40°C operating temperature range, while humidity levels can reach up to 80% without condensation. The module is suitable for installation up to 1000
Eaton Cutler-Hammer / PLCs / Power Defense
This device belongs to the Power Defense series and features a PD3 Global breaker type. It is constructed with a frame size of 3 and includes three poles for effective circuit management. The built-in thermal-magnetic trip technology provides both fixed thermal trip settings and adjustable magnetic
Eaton Cutler-Hammer / PLCs / Power Defense
This switch functions effectively at rated voltages of 600 VAC and utilizes a thermo-magnetic cutoff mechanism. It features a substantial interrupt rating of 65 kAIC at 480 VAC. Suitable for environments with relative humidity levels up to 80% (non-condensing), its design supports standard line and
Eaton Cutler-Hammer / PLCs / Power Defense
This molded case circuit breaker is designed for three-phase circuits and operates under a maximum AC voltage of 600 VAC and a DC voltage of 250 VDC. It incorporates thermal-magnetic trip technology, specifically marked with the trip unit code T297. The device has significant interrupt capacities: 6
Eaton Cutler-Hammer / PLCs / Power Defense
This circuit breaker, part of the Power Defense series, features a trip type of T298 and is classified as Class A. It has an interrupting capacity of 65 KAIC at 480 V AC, ensuring adequate protection for electrical systems. Designed with 2 poles and frame type 2, the breaker is suitable for a variet
Eaton Cutler-Hammer / PLCs / Power Defense
This circuit breaker offers an interrupt rating of 35 kAIC at 480 VAC, making it suitable for various applications. It utilizes standard line and load lugs for terminal connections. The unit operates effectively within a temperature range of -25°C to 70°C for both usage and storage.
Eaton Cutler-Hammer / PLCs / Power Defense
With three poles and a rated frequency of 50/60 Hz, this circuit breaker utilizes a fixed thermal-magnetic trip unit. It features a standard line and load setup and utilizes feed-thru lugs for connections, ensuring simplified installation. Additionally, it provides an interrupt rating of 25 kAIC at
Eaton Cutler-Hammer / PLCs / Power Defense
This circuit breaker conforms to Class A specifications and features a T298 trip type. It is designed as a single-pole breaker and can interrupt current up to 35 KAIC at 480 V AC levels. The breaker is configured with standard terminals for both line and load connections, ensuring easy installation.
Eaton Cutler-Hammer / PLCs / Power Defense
Designed specifically for three-phase systems, the PDG23F0030TFFJ features a fixed mounting style and supports feed-thru connections. It incorporates long-time and instantaneous trip functions and operates within a frequency range of 50 to 60 Hz. With a thermal magnetic protection type, this circuit