Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This series C circuit breaker supports three-phase configurations and features thermal magnetic trip units with long-time and instantaneous trip functions. The interrupting capacity stands at 65 kA at 240 volts AC and 14 kA at 277 to 480 volts AC. Its voltage range accommodates both 125 to 250 volts
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This accessory trip unit features three poles and operates with a voltage rating of 600 VAC or 250 VDC. With a magnetic trip range set between 4000 and 8000 amps, it offers reliable overload protection through its fixed thermal mechanism. The device is designed to function well within a frequency ra
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The LES3600LS features an RMS current sensing method and operates at frequencies of 50/60 Hz. It incorporates electronic protection with adjustable settings for long-time and short-time trip functions. This unit utilizes Digitrip RMS 310 technology for enhanced performance and is designed for integr
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This model includes three poles and a load side terminal connection. The FDC3060 features a T186 trip type for reliable protection. It provides an interrupt rating of 200 KAIC at 240V AC and 100 KAIC at 480V AC, making it suitable for significant fault current management.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is engineered with three poles and employs fixed thermal and magnetic trip mechanisms. The HJD3150 model mounts in a fixed position, features terminals for both line and load connections, and utilizes aluminum materials for terminals. Its operational frequency ranges between 50
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit operates at a voltage rating of 600 Volts AC and 250 Volts DC. The thermal magnetic trip unit provides long-time overload and instantaneous short circuit protection. With an interrupt rating of 65 kA at 240 Volts AC, it also supports ratings of 35 kA and 18 kA at 480 and 600 Volts AC, resp
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This three-pole circuit breaker features an F-frame size and utilizes load side terminals for secure connections. It supports a frequency range of 50 to 60 Hz and has a T186 trip type. Notably, it can handle high fault levels, with a 200 KAIC interrupt rating at 240 VAC and a 100 KAIC rating at 480
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker employs thermal magnetic trip technology and has a mounting style suited for panel applications. Rated for frequencies of 50/60 Hz, it supports 25 kA interrupt ratings at 600 V, making it ideal for safeguarding electrical systems. The KD3100 features lugs for line side connectio
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Featuring a mechanical operating mechanism, this auxiliary switch can be mounted on either the left or right pole configuration. It utilizes a terminal block connection style and provides auxiliary contacts configured as 2A/2B. This product is UL-approved and designed for field mounting to facilitat
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This three-pole circuit breaker is designed with a T186 trip type and resides within a K frame. The interrupt ratings are 65 kAIC at 480 V AC and 100 kAIC at 240 V AC. Constructed with aluminum terminals, it operates efficiently within a frequency range of 50 to 60 Hz and carries UL Listing for comp