469 results
Siemens / SENTRON
This three-pole circuit breaker operates at a frequency of 50/60 Hz and has a voltage rating of 480 V. It utilizes a thermal magnetic trip mechanism and is rated for trip ranges between 2500 and 5000 A. This model holds approvals from both UL and IEC standards, and its enclosure is rated IP40, indic
Siemens / SENTRON
The GF01ED60 ground fault relay serves as an electronic protection device, featuring instantaneous response capabilities. It complies with UL standards and operates through a continuous monitoring system. This basic relay kit has a fixed adjustment setting and provides a trip signal output that inte
Siemens / SENTRON
The 3VA4195-4ED34-0AA0 features three poles and offers protection against overcurrent through both long-time and instantaneous release functions. It has a current breaking capacity of 14 kiloamperes up to 600 volts AC and can support wire sizes ranging from 14 to 8 AWG. Its IP40 rating ensures adequ
Siemens / SENTRON
This circuit breaker is rated for a frequency range of 50 to 60 Hertz and has an ampere interrupt capacity of 10 kiloamperes at 240 volts AC. It uses a toggle actuator for operational control and can be mounted in panelboards via lug connections. This device supports wire sizes ranging from 10 to 1/
Siemens / SENTRON
This three-pole circuit breaker features a thermal magnetic trip unit with functions for both long-time overload protection and instantaneous short circuit protection. It maintains an interrupt rating of 85 kA at 240 Volts AC, 35 kA at 480 Volts AC, and 18 kA at 600 Volts AC, suitable for diverse el
Siemens / SENTRON
This model comes with two poles and utilizes a thermal magnetic trip unit for effective operation. It is classified under UL, CSA, and HACR standards, and provides both long-time overload and instantaneous short circuit protection. The FXD62B150 features a robust FXD6 frame type designed for high in
Siemens / SENTRON
This circuit breaker features a JD6 frame type, designed to be mounted securely using a bolt-on style. The device operates effectively at a frequency of 50 to 60 Hz and boasts an interrupt rating of 25KAIC at 600V and 35KAIC at 480V. It functions reliably within relative humidity levels not exceedin
Siemens / SENTRON
This device features three poles and ensures effective protection with an interrupting capacity of 14 KAIC at 600Y/347 V and 25 KAIC at 480 V. The trip unit is thermal-magnetic (TM210), configured for fixed overload protection at 70 A and short-circuit protection at 10 times the rated current. Rated