Schneider Electric / PowerPact
This circuit breaker features LSI trip functions allowing it to handle long-time, short-time, and instantaneous tripping. The unit satisfies international standards with certifications including UL, CSA, NOM, IEC, and CE. Offering connection via lugs for both line and load, it supports a chassis mou
Schneider Electric / PowerPact
This circuit breaker has a breaking capacity of 10 kA and is classified under Code B for additional specifications. Voltage ratings reach 240 V, while it operates within a frequency range from 50 to 60 Hz. The device employs thermal-magnetic trip unit technology and provides a rated impulse withstan
Schneider Electric / PowerPact
This circuit breaker has a thermal-magnetic trip unit technology. It has a breaking capacity of 25 kA and can handle magnetic tripping current of 1800 A. Its minimum and maximum operating frequencies range is 50 Hz to 60 Hz, respectively. The mounting mode is compatible with I-Line brackets, and it
Schneider Electric / PowerPact
This circuit breaker is rated for 70 A and supports a breaking capacity of 25 kA, categorized under breaking capacity code D. Operational frequencies range between 50 Hz and 60 Hz, with magnetic tripping capabilities set to 1800 A and a hold current of 1000 A. The device integrates thermal-magnetic
Schneider Electric / PowerPact
The circuit breaker operates at a rated operational voltage of 240 V AC and is capable of handling a network frequency of 50/60 Hz. With two poles, it utilizes an operating handle for control and is efficient with a thermal magnetic trip unit setup. It also features a magnetic tripping current of 24
Schneider Electric / PowerPact
This circuit breaker boasts a mechanical endurance of 1,000 cycles under load and 5,000 cycles without load. It functions effectively in ambient temperatures ranging from 40 to 70°C, provided the environment is non-condensing. The breaking capacity stands at 65 kiloamperes, optimized for 120 to 240
Schneider Electric / PowerPact
The HLL36100 circuit breaker has a magnetic hold current of 900 Amperes and a tripping current of 1,700 Amperes. It operates efficiently within an ambient temperature range of -25 to 70°C and has a storage temperature range from -50 to 85°C. Communication is available via Ethernet and Modbus, and lo
Schneider Electric / PowerPact
This trip unit features three poles and is designed for an operational voltage of 600 V. With an 80% short circuit breaking capacity, it is engineered for effective circuit protection. The design includes compliance with UL standards and can be installed within an enclosure rated NEMA 1, offering ad
Schneider Electric / PowerPact
The PGL36100U41A offers an operational voltage of 600 V AC, supporting 50/60 Hz applications. It has a continuous current rating set at 80%, with a solid-state configuration that includes long-time and instantaneous trip functions. The breaker can interrupt currents up to 18 kA at 600 V AC and featu
Schneider Electric / PowerPact
This three-pole circuit breaker, utilizing a P Frame design, supports an electronic trip unit labeled ET 1.0I. Featuring a push-to-trip button for manual operation, it is suitable for I-Line plug-in mounting. With an interrupt rating of 100 kA at 480V and 125 kA at 240V, it provides exceptional safe