471 results
Siemens / SENTRON
Configured with two poles, this device operates on a single-phase system. The ED42B045 offers an AIC rating of 18 KA at 480 V, ensuring effective protection against short circuits. Its mounting type is bolt-on, and connection is facilitated through bolt-on connections, suitable for easy installation
Siemens / SENTRON
This two-pole circuit breaker features a thermal magnetic protection system that includes long time and instantaneous trip functions. It employs a load side lug for terminal connection and uses a bolt-on connection type. Suitable for operation in environments with up to 80% humidity, the device can
Siemens / SENTRON
This circuit breaker features three poles and is equipped with thermal-magnetic trip technology for reliable fault detection. It maintains an interrupt rating of 65 kAIC at 480 VAC and 50 kAIC at 600 VAC. The unit can be mounted fixedly and connects via bolt-on methods, supporting straightforward in
Siemens / SENTRON
This trip unit features three poles and operates effectively with an interrupting capacity of 25 kA. It accommodates a frequency range from a minimum of 50 Hz to a maximum of 60 Hz. The device operates within an ambient temperature of 40°C and connects via tulip/plug-in terminals.
Siemens / SENTRON
This unit is constructed with an IP40-rated aluminum enclosure finished in ANSI 61 gray and supports horizontal mounting. It has a current rating of 60 A and is compatible with fuse classes R, H, and K. With four wires and three poles, this bus plug is suitable for versatile applications.
Siemens / SENTRON
This circuit breaker features a thermal-magnetic trip unit, which enhances protection against overload and short-circuit conditions. It consists of three poles and is suitable for bolt-on mounting applications. The interrupting ratings are impressive: 65 kA at 240 V AC, 35 kA at 480 V AC, and 25 kA
Siemens / SENTRON
This model incorporates three poles and operates under a thermal magnetic trip mechanism, providing both long-time and instantaneous protection. With an interrupting capacity of 18 kA at 480 volts, it is designed for dependable electrical safeguarding. The unit can accommodate wire sizes ranging fro
Siemens / SENTRON
This molded case circuit breaker contains three poles and is designed for three-phase systems. Rated for a maximum operating humidity of 80% (non-condensing), the circuit breaker is bolted onto mounts for secure installation. Thermal magnetic protection ensures reliable operation with long time and
Siemens / SENTRON
This model features three poles and a frequency rating of 50/60 Hz. It employs a thermal-magnetic trip unit for dependable operation. The mounting style is panel-mounted, and it includes load lug connections via bolt-on terminals. It has an interrupt rating of 42 kA at 480 volts AC, ensuring robust
Siemens / SENTRON
This circuit breaker contains three poles and utilizes a thermal-magnetic trip unit that provides reliable protection. It has a breaking capacity of 25 kA at 480 volts and 18 kA at 600 volts. The trip mechanism is fixed and non-interchangeable, and it supports a bolt-on connection type. The breaker