Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates effectively within two poles and supports frequencies from 50 Hz to 60 Hz. Both operating and storage humidity must not exceed 80% (non-condensing). The device is rated for installations up to 1000 meters above sea level.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed with three poles, the GHC3070 operates within a frequency range from 50 to 60 Hz. It features a T186 trip type and provides an interrupt rating of 14 kAIC at 480Y/277 VAC and 65 kAIC at 240 VAC. This G Frame circuit breaker is suitable for a variety of applications.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This device features two poles and utilizes a T186 trip mechanism. It supports frequency ranges from 50 to 60 Hz, providing flexibility in operation. With an interrupt rating of 100 kAIC at 240 VAC and 65 kAIC at 480 VAC, it ensures reliable protection against overcurrent faults.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a trip type designated as T186 and is housed in a J Frame. It accommodates three poles and operates within a frequency range of 50 to 60 Hz. With impressively high interrupt ratings of 100 kA at 240 VAC and 65 kA at 480 V, it provides essential protection against fault
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This model features a K frame and supports both line and load terminal types, contributing to its versatile installation capabilities. The circuit breaker is capable of managing frequencies from 50 Hz to 60 Hz, and is constructed with aluminum terminals for enhanced conductivity. It provides a high
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed with three poles, this breaker operates effectively within a frequency range of 50 to 60 Hz. It has an interruption rating of 100 kAIC at 240 VAC and 65 kAIC at 480 V. The HMDL3300 is suited for environments with up to 80% operating humidity and can be installed at altitudes of 1000 meters
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a K frame design and three poles. It is equipped with an interchangeable electronic trip (T186) and utilizes aluminum material for terminals. The device has an interrupting capacity of 200 kAIC at 240 VAC and 100 kAIC at 480 VAC, suitable for standard industrial applica
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is built on a JK frame type and incorporates a T39 type trip mechanism. It utilizes a 310+ Electronic LSG trip unit and offers solid-state protection, ensuring reliable operation in various applications. Designed to function in environments up to 40°C, the device is suitable for
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and operates within a minimum frequency of 50 Hz and a maximum frequency of 60 Hz. The T186 trip unit is used for fixed thermal and magnetic tripping operations. Rated interrupting capacities significantly enhance its protection: 65 kAIC at 240 VAC and 50 kA
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The device features three poles and utilizes a T186 trip unit with fixed thermal and fixed magnetic trip types. It can withstand interrupting capacities of 65 kAIC at 240 VAC and 50 kAIC at 480 VAC. The MDL3700 operates at a maximum frequency of 60 Hz and supports a minimum frequency of 50 Hz, makin