714 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This alarm switch operates within a temperature range of 0°C to 40°C for both active use and storage. It can withstand humidity levels up to 80% without condensation and is rated for installation at altitudes up to 1000 meters above sea level. The contact configuration includes 1M/1B, allowing for v
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a 2-pole configuration and incorporates fixed thermal and magnetic trip types. It's designed to function within a relative humidity range of 5% to 95% without condensation, ensuring reliable operation in varying environments.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is designed as part of the Series C lineup and is classified under the KDB type with a frame size of K-Frame. The configuration is a complete breaker with three poles and a thermal-magnetic trip mechanism. Rated for both AC and DC applications, it boasts an interrupting capacity
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features two poles and includes load-side standard pressure lugs for easy installation. Its interrupting capacities are notable, with ratings of 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, 25 kAIC at 600 VAC, and 22 kAIC at 250 VDC. The trip type combines fixed thermal and fixed ma
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker, featuring three poles, operates effectively in a three-phase setting. It has a weight of 4.4 lbs and a voltage rating of up to 600 VAC for AC and 250 VDC for DC applications. The interrupting capacity is rated at 100 kAIC for 240 VAC and 65 kAIC for 480 VAC, ensuring robust fau
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features both fixed thermal and fixed magnetic trip types, allowing for long-time and instantaneous trip functions that enhance protection. It has an interrupting capacity of 65 kAIC at 240 VAC and 22 kAIC at 480 VAC, ensuring safety in various applications. Additionally, it off
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed to handle voltages of up to 600 VAC and 250 VDC, the HFD2035 circuit breaker is equipped with fixed thermal and magnetic trip types. It features an impressive interrupting capacity of 100 kAIC at 240 VAC and 65 kAIC at 480 VAC, ensuring comprehensive protection in case of fault conditions.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This auxiliary switch features two normally closed (N.C.) contacts and two normally open (N.O.) contacts. The device is built to fit within the Series C K frame and HMCP configurations, making it versatile for different installations. It weighs 0.35 lbs and utilizes a terminal block connection type,
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The FD3025 circuit breaker features three poles and operates with fixed thermal and magnetic trip types. It provides high interrupting ratings of 65 kAIC at 240 VAC and 35 kAIC at 480 VAC, suitable for various applications with frequencies between 50 Hz and 60 Hz.