714 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case switch incorporates a three-pole design and functions with an AC voltage rating up to 600 VAC and a DC voltage rating of 250 VDC. It features various interrupting capacities at different voltages, including 100 kAIC at 240V AC and 65 kAIC at 480V AC.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This device includes three poles and is built on a JG frame. For interrupting capacity, it provides 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, and 25 kAIC at 600 VAC. The electronic Digitrip 310 RMS trip unit offers various protection functions, including long-time and short-time protection, ensuring
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a three-pole configuration and is rated for three-phase applications. Its interrupting capacity is rated at 65 kAIC for 240 VAC, 35 kAIC at 480 VAC, 25 kAIC at 600 VAC, and 22 kAIC at 250 VDC. The breaker incorporates both fixed thermal and magnetic trip units.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This two-pole circuit breaker has a K-frame and responds to 50/60 Hz frequency ratings. Its interrupting capacity is rated at 65 kAIC for 240 Vac and 10 kAIC at 250 Vdc, providing effective protection against overloads. This device is UL Listed for enhanced safety standards.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates on a two-pole system and is encased in durable glass polyester material. It features a frequency rating of 50/60 Hz and a trip type identified as T186. The device meets stringent safety certifications, being UL Listed, thereby ensuring its reliability in various electri
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This K-frame designed unit includes two poles and can manage various interrupting ratings: 10 kAIC at 250 VDC, 65 kAIC at 240 VAC, 35 kAIC at 480 VAC, and 25 kAIC at 600 VAC. The trip mechanism is a combination of fixed thermal and fixed magnetic types, allowing it to effectively identify overload c
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates at 240 VAC and 125 VDC, with an interrupting capacity of 65 kAIC for fault protection. Designed as a thermal magnetic trip unit, it features a robust F frame type construction. The ED3030 functions effectively with a frequency range of 50 to 60 Hz.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit utilizes a T186 trip type and is designed for panel mounting. It features line and load terminals along with a sturdy handle actuator. The breaker is capable of handling high interrupting ratings, reaching 65 kAIC at 480 Vac and 100 kAIC at 240 Vac, ensuring reliable circuit protection. It
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This single-pole circuit breaker features a frame size designated as Frame G. It has a surface mounting style and operates at frequencies of 50/60 Hz. The trip type is T186, and it provides an interrupting capacity of 14 kAIC at 277 Vac. Its design is optimized for single-phase use, with a maximum t
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and is rated for 240 VAC and 125 VDC, making it versatile for various applications. It has an interrupting capacity of 100 kAIC at 240 VAC, providing reliable circuit protection. The trip mechanism is thermal-magnetic, with a frequency range of 50 Hz to 60 H