1222 results
Allen Bradley / PLCs / 140G MCB
This circuit breaker operates within a current range of 60 Amps and has an interrupting rating specific to the trip unit. It features a rated insulation voltage of 1000 V and can withstand impulse voltages of up to 8 kV. Weighing 3.53 pounds, it supports a mechanical life of 240 operations and an el
Allen Bradley / PLCs / 140G MCB
This circuit breaker, classified as H-frame, supports a current range of 160 Amps. It possesses an interrupting rating of 35 kA, ideal for managing significant fault currents. With a rated insulation voltage of 1000 volts and impulse withstand voltage of 8 kV, this unit's weight is approximately 3.5
Allen Bradley / PLCs / 140G MCB
Rated for a 60 Amp current, the 140G-H3I3-C60 operates with an interrupting capacity of 35 kA. Its insulation voltage is rated at 1000 V, while it can withstand impulse voltages of 8 kV. Additionally, this model weighs 2.65 pounds and supports a mechanical life of 240 operations per hour and an elec
Allen Bradley / PLCs / 140G MCB
This circuit breaker features four poles and operates within a current range of 110 A. It is designed for a rated insulation voltage of 800 V and has an impulse withstand rating of 8 kV. Weighing 5.73 pounds, the device is equipped with fixed thermal and magnetic protection types. The thermal trip i
Allen Bradley / PLCs / 140G MCB
This circuit breaker model features a 25 kA interrupting rating, which helps manage short circuits safely. It can handle rated currents of 25 A, additional current ratings of 250 A, and insulation voltage ratings of 1000 volts. The breaker is built to tolerate impulse voltages of up to 8 kV, ensurin
Allen Bradley / PLCs / 140G MCB
This four-pole circuit breaker supports a current rating of 70 A and a maximum current of 250 A. It is rated for an insulation voltage of 1000 V, and its impulse withstand voltage rating is 8 kV. It is designed to be resilient against voltage surges. With a compact weight of 7.72 lbs., this breaker
Allen Bradley / PLCs / 140G MCB
This circuit breaker is designed with fixed thermal and magnetic protection mechanisms. It operates with 70 A of rated current and 250 A of maximum current and is rated for an interrupting capacity of 35 kA. The device can withstand a rated insulation voltage of 1000 V and an impulse withstand volta
Allen Bradley / PLCs / 140G MCB
Designed with a J frame, the 140G-J3F4-C80 model demonstrates adjustable thermal and magnetic protection types. Its current range is rated at 80 Amps, while it supports insulation rated up to 1000 Volts. This breaker withstands impulse voltages of 8 kV and weighs 7.72 pounds, highlighting solid cons
Allen Bradley / PLCs / 140G MCB
This four-pole circuit breaker operates at a current range of 170 A. It is equipped with adjustable thermal and magnetic protection types. Rated for 1000 volts, it also withstands impulse voltages of 8 kV. Weighing 7.72 pounds, it performs reliably with a mechanical lifespan of 240 operations per ho
Allen Bradley / PLCs / 140G MCB
Engineered with four poles, this breaker operates in a current range of 100 Amps. It includes adjustable thermal and magnetic protection options, allowing for fine-tuning to specific applications. It can operate at rated insulation voltages up to 1000V and withstand impulse voltages of 8 kV. At a we