714 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Engineered with a three-pole configuration, this circuit protector is compatible with 3-phase systems. The magnetic trip range spans from 9 A to 30 A, providing flexible operation in various applications. With an interrupting rating of 65 kAIC at 480 VAC, this unit ensures reliable fault interruptio
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This Series C circuit breaker has a current rating of 25 A and is suitable for use at voltages of 480Y/277 VAC, along with 125/250 VDC. The GHB2025 is designed to be connected using a bolt-on method and functions effectively within a frequency range of 50 to 60 Hz. With UL approval, the breaker exhi
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit includes three poles and is rated for 50/60 Hz operation. It utilizes aluminum for terminal construction and has a T186 trip type. The circuit breaker can manage wire sizes between 250 and 500 kcmil for copper or aluminum conductors, with an interrupt rating of 35 kAIC at 480 VAC and 65 kA
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This product is housed in a frame size categorized as J-K and encompasses three poles for circuit protection. The operating temperature range is between −20°C to +55°C, making it suitable for various environments. The unit can operate up to an altitude of 2,000 meters and includes LED status indicat
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit comprises two poles and is intended for load side terminal connections. It functions effectively across a frequency range of 50 to 60 Hz and falls under the F frame type category. The EDH2125 breaker is equipped to handle substantial electrical loads while maintaining safety and compliance
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker accommodates a maximum of 480 VAC and 250 VDC, making it versatile for various applications. With a fixed thermal-magnetic trip mechanism, it ensures consistent protection against overloads. The EHD3060 includes load lugs for quick terminal connections and supports a 14 kA inter
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed with a J-K frame, the HMCP050K2C features a magnetic trip range between 50 and 500 amperes. It operates within a voltage capacity of 600 volts AC and 250 volts DC. This circuit protector provides an interrupting capacity of 65 kA for AC applications at 480 volts and 22 kA for DC application
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This trip unit features three poles and is designed for compatibility with MDL, HMDL, CMDL, and CHMDL frame types. It incorporates advanced Digitrip 310 RMS technology. The LSG trip functions include long-time, short-time, and ground fault protections, ensuring reliable operation and safety across a
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker contains two poles and operates within a single-phase system. It features interrupting ratings of 18 kAIC at 240V AC and 14 kAIC at both 480V AC and 600V AC. Designed for a frequency rating of 50/60 Hz, this breaker uses a bolt-on mounting connection with load side lugs for term
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case breaker trip unit is compatible with breaker frames such as Type MDL, HMDL, and HMDLDC. It provides thermal magnetic protection and incorporates LI trip functions for long-time and instantaneous responses. This trip unit is designed to function effectively in temperature ranges from