49 results
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
Rated for 20 amperes, this ground fault circuit breaker utilizes pigtail leads for connections. It features a thermal magnetic protection mechanism and supports both long time and instantaneous trip functions. The interrupting capacity is rated at 10 kAIC at 240 volts, and it accommodates wire sizes
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
This circuit breaker features three poles and operates at an electrical phase of 3-phase. Compliance with a short circuit interrupt capacity of 10,000 Amps enhances its reliability. It is compatible exclusively with Legacy Type PB panelboards and requires bolt-on connections for installation.
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
As a thermal magnetic circuit breaker, the CH2110 provides effective interruption with a maximum rating of 10 KAIC. This unit functions in a one-phase setting and features LI functionality for both long-time and instantaneous trip conditions. Designed for ease of installation, it uses a plug-in conn
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
This circuit breaker features two poles and a common trip type, offering robust ground fault protection as an equipment protector. With an interrupt rating of 10 kAIC, it ensures reliable performance under fault conditions. The enclosure is rated NEMA 3R, making it suitable for outdoor applications,
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
Operating with a nominal discharge current of 20 kA, this surge protection device provides extensive protection with a maximum surge current of 108 kA. The device manages voltages at 150 V L-N and 300 V L-L while securing lines up to 600 V L-N, 1000 V L-L, and 800 V N-G. It is suitable for single-ph
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
Configured specifically as a main lug loadcenter, this model is ideal for single-phase installations. It offers a robust interrupt rating at 25 kAIC and is equipped with copper bus material, ensuring efficient electrical conduction. The loadcenter is designed to house single-pole circuit breakers an
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
Featuring two poles, this circuit breaker is utilized for branch circuits and employs thermal magnetic protection strategies. It has a 10 kAIC interrupt rating. This model can accommodate a wire size range of 14 to 6 AWG for both copper and aluminum conductors.
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
The CHB3100 includes a three-pole configuration and has a substantial interrupt rating of 10 KAIC. It is designed for bolt-on installation and operates effectively in environments with up to 80% humidity. Operating at altitudes of up to 1000 meters above sea level, this circuit breaker is suitable f
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
This 2-pole circuit breaker operates effectively within a disrupting rating of 10 KAIC, ensuring reliable protection against electrical faults. The CHB290 utilizes a bolt-on connection system for simple install and integrates thermal magnetic protection that includes both long-time and instantaneous
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
This circuit breaker integrates a common trip mechanism and features two poles. It includes load side and line side terminals for streamlined connections. Rated for a ground fault sensitivity of 5 mA with an interrupting capacity of 10 kAIC, it supports wire sizes from #14 to #6 AWG for copper or al