722 results
Schneider Electric / Square D
This meter main is rated for a maximum current of 400 A and can withstand short circuit conditions up to 25 kA. The system features a main breaker with a 200 A rating and is configured for 1-phase operation. With a total of 8 spaces, it allows for a maximum of 16 circuits. The unit utilizes a Class
Schneider Electric / Square D
Constructed for reliability, the EDB36100 features a breaking capacity of 14 kiloamperes and utilizes a thermal-magnetic trip unit for enhanced functionality. It operates effectively in non-condensing environments at ambient temperatures ranging from 0 to 40°C, supporting both aluminum and copper wi
Schneider Electric / Square D
This transformer supports both three-phase and single-phase electrical systems. It operates at a frequency of 60 Hz and features a resilient design with resin encapsulation. The enclosure has a NEMA 3R rating, suitable for both indoor and outdoor placement.
Schneider Electric / Square D
This surface-mount switch features three poles and supports a line-rated current of 1,200 amperes. The NEMA 3R-rated enclosure is constructed from galvannealed steel. The switch accommodates copper or aluminum wire, specifically sized for 3 AWG, allowing for a maximum short-circuit current of 200 ki
Schneider Electric / Square D
The Schneider Electric 9070TF1000D1 transformer is engineered for single-phase applications, delivering a power rating of 1000 VA. With a voltage regulation of ±5%, it operates across a frequency spectrum of 50/60 Hz. It features a temperature rise specification of 115 °C and insulation temperature
Schneider Electric / Square D
Featured in the Square D series, this manual starter operates as a non-reversing starter, supporting three-phase systems. It has an overload relay made of melting alloy, ensuring reliable operation and protection. Rated for use with copper wire sizes ranging from 8 to 14 American Wire Gauge, it has
Schneider Electric / Square D
The H366NR switch model features a 600 A current rating with a voltage capacity of 600 V AC/DC. It offers a high short-circuit current rating of 200 kA for R or J fuses, supporting motor actions of up to 500 HP at the specified voltage. Its construction allows for connections from AWG 3/0 to 500 kcm
Schneider Electric / Square D
This panelboard interior features 54 available spaces and is designed as a main lugs type of load center. It incorporates copper busbars and meets standard compliance with UL listing and CSA certification. NEMA 1 rated, this panelboard can be mounted to surfaces or flush against walls and is also a
Schneider Electric / Square D
With a resistive amperage of 50 A, the 8910DPA42V02 contactor supports a range of coil voltage ratings at 110/120 VAC with frequencies of 50/60 Hz. Its rated horsepower for one-phase systems is 3 HP at 115V and 7.5 HP at 230V. In three-phase configurations, it handles up to 10 HP at 230V, 20 HP at 4
Schneider Electric / Square D
This single-phase transformer features a secondary voltage output of 120/240 V. It has an aluminum winding and supports a maximum insulation temperature of 220 °C, with a temperature rise of 150 °C during operation. The unit features a NEMA 2 enclosure type for adequate protection, with dimensions o