714 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates at a rated voltage of up to 600 VAC and features a frequency range of 50 to 60 Hz. The interrupt capacity is rated at 100 kAIC for 240 VAC and 65 kAIC for 480 VAC. It is installed in panel or switchboard configurations, but does not come with terminals included. The uni
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is configured with three poles and operates in 3-phase systems. It features a K Frame size and has a thermal magnetic trip mechanism. Interrupting capacities reach 65 kAIC at 240 VAC and 10 kAIC at 250 VDC, ensuring robust safeguarding against electrical faults.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The circuit breaker is rated for 600 volts AC and 250 volts DC, with interrupt capacities of 100 kA at 240 volts AC, 65 kA at 480 volts AC, and 35 kA at 600 volts AC. Designed for adaptability, it has a thermal magnetic trip unit offering long-time and instantaneous protection. The HLD3500 is suitab
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This equipment features three poles and operates with a voltage rating of 600 VAC or 250 VDC. It has a magnetic trip type with a trip range spanning from 875 to 1750 A. The product fits within a J-frame and corresponds to a NEMA size 5 starter. It includes both line and load terminal types for insta
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case circuit breaker is equipped with a trip type that includes fixed thermal and magnetic functions. It boasts an interrupting capacity of 65 kAIC at 240 VAC and 14 kAIC at 480Y/277 VAC. The GHB3060S1 is designed for bolt-on mounting and can function within a frequency range of 50 to 60
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The FDC3090 circuit breaker is structured with three poles and is utilized for both AC and DC applications, capable of handling up to 600 VAC and 250 VDC, respectively. It features a fixed thermal and magnetic trip mechanism with long-time and instantaneous trip functions. Interrupting capacities fo
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for left-hand mounting, this auxiliary switch instructs its operation at both 0°C and 40°C limits. It can function in environments with humidity of 80% and has an installation altitude limit of 1000 meters above sea level. The A2X1LPK has been constructed with storage conditions in mind, ma
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker can handle a diverse frequency range from 50 Hz to 60 Hz. It features a thermal-magnetic trip unit that provides both long-time and instantaneous trip functions. The interrupting ratings are 65 kAIC at 240 VAC, 35 kAIC at 480 VAC, and 18 kAIC at 600 VAC, ensuring robust protecti
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This device features a single pole and operates with a trip type labeled T186. It has an interrupt rating of 18 KAIC at 240 VAC and 14 KAIC at 480 VAC, ensuring effective protection against fault conditions. The rated voltage for this breaker is 277 V, and it operates efficiently within a frequency