722 results
Schneider Electric / Square D
This three-phase transformer is built for wall mounting and is enclosed in a NEMA 3R casing made of painted sheet steel. It has a temperature rise specification of 115 °C and a self-ventilated dry-type cooling method. With an insulation temperature rating of 356 °F (180 °C), the transformer is robus
Schneider Electric / Square D
This industrial control transformer operates at a primary voltage of 240/480V and provides a secondary output of 120V. It has a power rating of 300 VA, with a temperature rise of 80 °C. The unit is designed with foot mounting and features UL listing and CSA certification, ensuring compliance with sa
Schneider Electric / Square D
This 1-phase transformer has a temperature rise of 115 degrees Celsius during operation. It is constructed with copper windings for enhanced efficiency and electrical connections are achieved using screw clamp terminals. Compliance with CSA and UL standards ensures safety and reliability. With an op
Schneider Electric / Square D
This load center is rated for a maximum short circuit current of 22 kA and operates at a voltage of 120/240 VAC. Built from welded galvanized steel, its enclosure measures 758 mm in height and 375 mm in width, achieving a NEMA 3R protection rating. This product is UL listed for safety and reliabilit
Schneider Electric / Square D
This circuit breaker consists of 2 poles and is classified as a standard type. It has a notable interrupt rating of 22 kA and occupies 4 panel spaces. It supports an array of wire sizes, ranging from AWG 1 to 300 kcmil, and requires a tightening torque of 28.3 Nm. The listed dimensions are 145 mm in
Schneider Electric / Square D
The i-Line busway features a ground busbar and operates with a fusible disconnect device. It has UL and CSA certifications, ensuring compliance with essential safety standards. This system can be installed vertically and can endure an operating and storage humidity of up to 80%. It is suitable for u
Schneider Electric / Square D
This lighting contactor supports a maximum inrush power of 150 VA at 60 Hz and 25 VA at 50/60 Hz. With a tungsten current rating of 20 Amps and a fluorescent current rating of 30 Amps, it ensures effective operation. The 8903LXG40V04 is designed for clean indoor environments without exposure to corr
Schneider Electric / Square D
This miniature circuit-breaker incorporates a thermal-magnetic trip unit rated at 875 A, with a holding current capacity of 270 Amps. It requires only 2 spaces and mounts with a bolt-on method, making installation straightforward. Designed for use with wire sizes ranging from AWG 14 to 6 for copper
Schneider Electric / Square D
This fuse holder supports a line rated current of up to 200 A and accommodates conductors from AWG 4 to 250 kcmil, including both aluminum and copper. With a protective class of IP20, it can operate within an ambient temperature range of -20°C to +60°C and withstands short-circuit conditions up to 1
Schneider Electric / Square D
The LC11021 is a circuit breaker shunt trip from Schneider Electric's Square D series, designed to provide overload and short-circuit protection. It operates at frequencies of 50 to 60 Hz, and its operation temperature range spans from 0°C to 40°C. This model includes a manual reset status indicator