714 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is configured with three poles, making it suitable for 3-phase systems. It has an interrupt rating of 100 kAIC at 240 VAC and 65 kAIC at 480 VAC, ensuring reliable fault protection. The trip mechanism is thermal-magnetic, and the terminals are made of aluminum, designed for both
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and utilizes an F frame type design. Protection is provided by fixed thermal and fixed magnetic trip types. It includes lugs for both line and load terminal connections and boasts an interrupting capacity of 65 kAIC at 240 VAC.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker has a rated interrupting capacity of 65 kAIC at 240 VAC, ensuring safety during fault conditions. It features a trip mechanism using both fixed thermal and magnetic settings, suitable for various applications. It is mountable using panel mount or bolt-on methods, with a frequenc
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case circuit breaker features a design built for two poles and operates effectively in circuits up to 600 VAC and 250 VDC. It provides a trip type of fixed thermal and fixed magnetic, with an interrupting capacity of 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, and 25 kAIC at 600 VAC.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This single-pole circuit breaker is engineered for surface mounting and operates effectively in both 50 Hz and 60 Hz frequency conditions. It has an interrupt rating of 14 kAIC when tested at 277 Vac and maintains operational stability at temperatures up to 40 deg C. The circuit breaker is identifie
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case switch features three poles and utilizes fixed thermal and magnetic trip types. It has an interrupting rating of 18 kAIC at 240 VAC and 14 kAIC at 480 VAC, with a capacity of 10 kAIC at 250 VDC. Designed for use in systems operating within a frequency range of 50 to 60 Hz, the EHD31
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed with two poles, this breaker provides essential protection with a fixed thermal and fixed magnetic trip type. It has significant interrupting capacities of 65 kAIC at 240 VAC and 14 kAIC at 480Y/277 VAC. This unit supports a frequency range of 50 to 60 Hz and weighs 1.15 lbs.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and has rated voltage specifications of 480Y/277 VAC for AC and 125/250 VDC for DC. It offers an interrupting capacity of 65 kAIC at 240 VAC and 14 kAIC at 480 VAC. The trip mechanism incorporates both fixed thermal and fixed magnetic functions with a long-t
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features an F Frame size and includes three poles for effective electrical management. With fixed thermal and magnetic trip units, the HFD3020L is built for reliable protection. Its interrupting ratings vary based on voltage: 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, and 25 kAIC