259 results
Allen Bradley / PLCs / 140U MCB
This circuit breaker is optimized for frequencies ranging from 50 Hz to 60 Hz. It has exceptional interrupting ratings, achieving 100 kA at 240 V and 50 kA at 600Y/347V. This breaker operates effectively in environments with temperatures ranging from 0 °C to 50 °C.
Allen Bradley / PLCs / 140U MCB
This 3-pole circuit breaker is designed with a J frame and offers a minimum magnetic trip current of 800 A and a maximum of 1600 A. It operates effectively in temperatures ranging from -25°C to 60°C, making it suitable for various environments. Horsepower ratings are available at 25 Hp for 200 VAC,
Allen Bradley / PLCs / 140U MCB
This circuit breaker features a two-pole configuration and belongs to a D frame size. It has a magnetic trip setting between 15 to 20 times the rated current. Designed for high performance, it has a breaking capacity of 65 kA at 525 V and 18 kA at 690 V, along with an interrupting rating of 100 kA a
Allen Bradley / PLCs / 140U MCB
This molded case circuit breaker comes equipped with three poles. It operates within a frequency range of 50 to 60 Hz. The device has several breaking capacities, including 200 kA at 220-240 V, 100 kA at 380-415 V, and 35 kA at both 525 V and 600/347 V.
Allen Bradley / PLCs / 140U MCB
The 140U-I3C3-D12-S is an I-frame thermal-magnetic circuit breaker with a non-adjustable magnetic trip. This breaker has been manufactured and designed by Allen Bradley and included in the 2100 combination series. This breaker has a continuous current rating of 125 Amps and a horsepower rating of 20
Allen Bradley / PLCs / 140U MCB
The 140U-H6C3-D12 circuit breaker is a fixed-thermal and fixed-magnetic circuit breaker that has been manufactured and designed by Allen Bradley. This breaker has been designed to operate with a high interrupting rating that provides overload and short-circuit currents to different devices that run
Allen Bradley / PLCs / 140U MCB
The Allen Bradley 140U circuit breaker with the product code 140U-I0C3-C30 is a thermal-magnetic protection device with a non-adjustable magnetic trip. The unit has a magnetic trip range of 500 to 1000 Amps and a continuous current rating of 30 Amps. This circuit breaker is built with a frame size o
Allen Bradley / PLCs / 140U MCB
This circuit breaker features a frame size classified as D and provides an interrupt rating of up to 65 kA. It incorporates fixed thermal and magnetic protection mechanisms for reliable circuit safeguarding. Additionally, it operates effectively in humid environments with non-condensing conditions o
Allen Bradley / PLCs / 140U MCB
This model is rated for a maximum current of 30 Amperes and a continuous rated current of 5 Amperes. It provides an interrupt rating of 100 kiloamperes and supports a supply voltage of 480 Volts AC. Mountable on a DIN rail, this circuit breaker functions effectively at a frequency range of 50 to 60