86 results
Eaton Cutler-Hammer / PLCs / Power Defense
The molded case circuit breaker provides a high interrupt rating of 65 kAIC at 480 VAC, supporting reliable operation within various systems. It is designed to function optimally within a temperature range of -20°C to 70°C for operating conditions and can be safely stored between -40°C and 70°C. Thi
Eaton Cutler-Hammer / PLCs / Power Defense
This circuit breaker has a frame size classified as Frame 3 and is capable of handling up to 600 V AC and 250 V DC. It utilizes thermal-magnetic trip technology, with a fixed thermal trip and adjustable magnetic trip. The unit includes standard line and load terminals for easy connections and featur
Eaton Cutler-Hammer / PLCs / Power Defense
This circuit breaker features a robust thermal-magnetic trip unit, making it ideal for various applications. It is built with three poles and has a frame size categorized as Frame 3. The interrupting capacity is rated at 65 kAIC when handling 480 VAC, ensuring safety in fault conditions.
Eaton Cutler-Hammer / PLCs / Power Defense
The device features three poles and a thermal-magnetic trip unit to enhance protection from overloads and short circuits. It has an interrupting capacity of 35 kAIC at 480 VAC, ensuring reliable performance under fault conditions. The circuit breaker can be panel-mounted and is compatible with stand
Eaton Cutler-Hammer / PLCs / Power Defense
This device features three poles and is constructed in Frame Size 1, ensuring compatibility with multiple setups. It has an interrupt rating of 65 kAIC, providing reliable performance under fault conditions. The thermal magnetic trip unit guarantees efficient overload and short-circuit protection.
Eaton Cutler-Hammer / PLCs / Power Defense
This circuit breaker features three poles and employs a frame type labeled as 3 Frame. Trip mechanisms include fixed thermal and adjustable magnetic options. With interrupting capacities of 200 kAIC at 240 VAC, 100 kAIC at 480 VAC, and 65 kAIC at 600 VAC, it ensures effective fault interruption.
Eaton Cutler-Hammer / PLCs / Power Defense
This circuit protection device features two poles and is rated for an interrupting capacity of 65 kAIC at 240 VAC and 35 kAIC at 480 VAC. It employs both fixed thermal and magnetic trip types to ensure reliable safety operations. Operationally, it accommodates frequencies from 50 Hz to 60 Hz, making
Eaton Cutler-Hammer / PLCs / Power Defense
As a part of the Power Defense series, the PDG33G0225TFAJ model falls under the PD3 Global breaker type and is built with a frame size classified as Frame 3. Its interrupt ratings include 65 kA at 240 VAC and 18 kA at 600 VAC, which demonstrate its capacity to handle significant fault currents. Desi
Eaton Cutler-Hammer / PLCs / Power Defense
This terminal kit accommodates three poles and has a Frame 6 type and J–K frame size. It is classified as a PD6 Global breaker and utilizes HW tunnel terminals made from aluminum. The kit is compatible with both copper and aluminum conductors, supporting Class B or C conductors, with six conductors
Eaton Cutler-Hammer / PLCs / Power Defense
This circuit breaker includes a three-pole configuration and offers varying interrupting capacities, with 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, and 35 kAIC at 600 VAC. The protection function is provided as long-time and instantaneous (LI), ensuring reliable operation during overload and fault co