197 results
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This 3-pole circuit breaker operates effectively at temperature levels reaching 40°C and offers adjustable magnetic trip settings combined with a fixed thermal trip mechanism. It has an interrupting capacity of 100 kAIC at 240 VAC and 35 kAIC at 600 VAC, making it suitable for industrial application
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker features three poles and offers reliable operation in key applications. It has thermal-magnetic trip functionality and possesses significant interrupting capacity: 65 kAIC at 240 VAC, 35 kAIC at 480 VAC, and 18 kAIC at 600 VAC. The device is designed to handle demanding conditio
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This three-pole circuit breaker supports frequencies from 50 Hz to 60 Hz. Its interrupting capacity varies by voltage: 125 kAIC at 240 VAC, 65 kAIC at 480 VAC, and between 35 kAIC to 50 kAIC at 600 VAC. The device utilizes an Electronic Digitrip 310 RMS for advanced trip functions, including Long-Ti
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This three-pole circuit breaker employs fixed thermal and magnetic trip types for protective measures. It showcases an interrupting capacity of 85 kAIC at 240 VAC, 35 kAIC at 480 VAC, and 22 kAIC at 600Y/347 VAC, making it robust under fault conditions. The operational frequency range is between 50
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker offers a robust interrupting capacity, rated at 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, and 35 kAIC at 600 VAC. Weighing 16 lbs, it is equipped with line and load terminal types to facilitate various installation needs.
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This breaker operates across a voltage range of 600 V to 690 V AC and has impressive interrupting capacities, rated at 125 kAIC for 240V AC, 65 kAIC for 480V AC, and between 35 kAIC and 50 kAIC for 600V AC. It includes trip functions for long-time, short-time, and ground fault protection. The device
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This shunt trip unit is compatible with RG-frame models and mounts on the right side. It features pigtail leads for connection and supports both 24 VAC and 24 VDC control voltages. With an operating frequency ranging from 50 to 60 Hz, it also provides protection from residual ground faults and 30 mA
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
Designated as a molded case circuit breaker, the NGH308036E consists of three poles and operates using an Electronic Digitrip 310 RMS trip unit. This model supports trip functionalities such as long-time, short-time, and instantaneous (LSI) protection. It has an impressive interrupt rating of 100 kA
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker includes a three-pole configuration and has a fixed trip unit. The EGB3040FFB is a thermal magnetic type, ensuring reliable protection. Its interrupting ratings are 25 kA at 240V and 18 kA at 480V, allowing for efficient circuit management. Connections are made via bolt-on metho
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This 3-pole electronic MCCB is designed to function within a frequency range of 50-60 Hz. The trip unit utilized in this breaker is the Digitrip 310+ LSI, providing advanced protection features. It supports various interrupting capacities, including 125 kA at 240 Vac, 65 kA at 480 Vac, and 50 kA at