404 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The trip unit features three poles and includes long-time and instantaneous tripping functions (LI). With a frequency rating between 50 and 60 Hertz, this thermal magnetic trip unit is compliant with UL standards and is compatible with multiple circuit breaker frames, including CKD and KD.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates within a frequency range of 50 to 60 Hz and supports 3-phase configurations. It is rated for an AC voltage of 480Y/277 VAC and a DC voltage of 125 to 250 VDC. Additionally, the G Frame size ensures compatibility with existing installations while being able to function i
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This series C circuit breaker supports three-phase configurations and features thermal magnetic trip units with long-time and instantaneous trip functions. The interrupting capacity stands at 65 kA at 240 volts AC and 14 kA at 277 to 480 volts AC. Its voltage range accommodates both 125 to 250 volts
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit features three poles and operates under a thermal-magnetic trip mechanism, known as the TI85 type. It supports installation at altitudes up to 1000 meters above sea level and is designed to function within specific temperature limits of 0°C to 40°C for both operation and storage.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker trip unit operates within a voltage rating of 600 VAC and includes a fixed trip type labeled T185. It is designed for 3-phase systems and effectively handles frequencies from 50 to 60 Hz. Rated for an ambient temperature of up to 40 °C, it provides both long-time thermal and ins
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates with three poles and is suitable for 3-phase installations. With a frequency rating of 50/60 Hz, the FDC3225 is designed for panel mounting. It connects using a bolt-on method to ensure secure installation and includes protection against overload conditions and short-ci
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case circuit breaker is engineered with fixed thermal and fixed magnetic trip types for dependable operation. The interrupting capacity is rated at 14 kAIC for 480Y/277 Vac and 65 kAIC at 240 Vac, suitable for handling substantial fault currents. It complies with UL certification standar
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates at a maximum AC voltage of 600 VAC with a feed-thru connection type. It features a K-frame design and is capable of providing magnetic-only protection. Additionally, it has a 35 kA AIC rating at 480 V, ensuring protection against fault currents. It is also suitable for
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This device features a 3-pole design with cable in/cable out wiring, ensuring flexibility in installation. Its interrupt ratings are 18kA at 240V and 14kA at 480/600V, making it capable of withstanding significant fault conditions. The mounting style is bolt-on, and it includes load connections via
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a magnetic trip unit that delivers instantaneous trip functions. With a current breaking capacity of 65 kiloamperes at 480 Volts AC, it's designed to handle demanding situations effectively. The breaker consists of three poles and has a feed-thru connection type, ideal