462 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker consists of three poles and features a K frame type. It employs a thermal magnetic trip unit for protection, providing long-time and instantaneous trip functions. The device has an interrupting rating of 65 kiloamperes at 240 volts AC and complies with UL and CSA safety standard
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This rating plug supports 3-pole breaker frames and is designed to be mounted easily by plugging into compatible trip units. It is engineered for use with several molded case circuit breaker frames, including LD, HLD, and others. The interrupting rating is 65 kAIC at 480 VAC, ensuring robust perform
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a single pole with a standard interrupt capacity class. With fixed thermal and magnetic trip technology, the EHD1020 effectively protects against overcurrent conditions. Terminal connections are made on the load side, and the device is designed for 50/60 Hz operation, c
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for robust applications, the EHD2030 features an frame type and includes a UL certification for quality assurance. It provides an interrupting capacity of 18 kAIC at 240V and 14 kAIC at 480V. This unit is suitable for installations up to 1000 meters above sea level, supporting diverse opera
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case circuit breaker is engineered with fixed thermal and fixed magnetic trip types for dependable operation. The interrupting capacity is rated at 14 kAIC for 480Y/277 Vac and 65 kAIC at 240 Vac, suitable for handling substantial fault currents. It complies with UL certification standar
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and is designed with both fixed thermal and fixed magnetic trip settings. The interrupting capacity is rated at 65 kAIC for 240V and 14 kAIC for 480Y/277V, ensuring reliable protection in fault conditions. Operating comfortably within a temperature range of
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This unit operates efficiently within a temperature range of 0°C to 40°C, with the same limits applied for storage conditions. It can function optimally under a maximum humidity of 80% without condensation. The device is suited for installation at altitudes not exceeding 1000 meters above sea level.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The trip unit features three poles and includes long-time and instantaneous tripping functions (LI). With a frequency rating between 50 and 60 Hertz, this thermal magnetic trip unit is compliant with UL standards and is compatible with multiple circuit breaker frames, including CKD and KD.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for robust applications, this circuit breaker holds an interrupt rating of 22 kAIC at 240 VAC. It accommodates a frequency range between 50 Hz and 60 Hz. The terminal type is specifically for load-side connections, and it is categorized under the F Frame type, which influences its physical
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This rating plug is appropriate for use with Digitrip RMS 310 systems and supports frequencies of 50/60 Hz. It features adjustable pickup ranges for ground fault and instantaneous protection, along with short delay and long delay settings for customized responses.