197 results
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This breaker can handle voltage ratings of 600Y/347 VAC, 240 VAC, and 480 VAC for AC applications, as well as 250 VDC for direct current. It features a thermal-magnetic trip type, which includes long-time and instantaneous trip functions. It boasts significant interrupting capacity ratings of 100 kA
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker supports an interrupting capacity of 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, and 35 kAIC at 600 VAC. It uses fixed thermal and magnetic trip types to ensure safety and performance. The unit connects through line and load lugs and is designed for use within a frequency range of
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This product is designed with an operational temperature rating of 40 degrees Celsius and an insulation voltage of 600 VAC. Additionally, it possesses an impressive interrupt rating of 85 kAIC at 240 Vac, 35 kAIC at 480 Vac, and 22 kAIC at 600Y/347 Vac. The circuit breaker is enclosed in Frame EG an
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This circuit breaker features two poles and utilizes thermal magnetic trip technology. It has a long-time and instantaneous trip function classified as LI. The interrupting capacity is rated at 100 kAIC for 240 VAC, 65 kAIC for 480 VAC, and 35 kAIC for 600Y/347V AC.
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This trip unit utilizes the advanced 310+ electronic LSI technology, which allows for long-time, short-time, and instantaneous trip settings. It can operate in temperature ranges from -20°C to 55 °C. The unit is designed for environments with relative humidity levels of 0% to 95%, provided they rema
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
This handle assembly is crafted for JG-Frame circuit breakers and complies with NEMA standards, including NEMA 1, NEMA 3R, and NEMA 12. It utilizes a through-the-door mounting method to ensure robust installation. Operational temperatures are rated from -20°C to 70°C, while storage temperatures rang
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
With three poles, this breaker features fixed thermal and magnetic trip types for reliable circuit protection. It has rated interrupting capacities of 35 kAIC at 240 VAC, 25 kAIC at 480 VAC, and 18 kAIC at 600Y/347 VAC. This device is designed for panel mounting and functions within frequency parame
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
The EGS2015FFG features a two-pole design with fixed thermal and magnetic trip types. Its interrupting capacity is rated at 85 kAIC for 240 VAC, 35 kAIC for 480 VAC, and 22 kAIC for 600Y/347 VAC. This device operates efficiently within a frequency range of 50 to 60 Hz and is equipped with terminals
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
Designed with fixed thermal and magnetic trip mechanisms, this circuit breaker ensures reliable protection against overcurrent conditions. It can handle interrupting ratings of 25 kAIC at 240 VAC, 18 kAIC at 480 VAC, and 10 kAIC at 250 VDC. The device weighs 2 lbs and is intended for unit mounting,
Eaton Cutler-Hammer / PLCs / Series G Circuit Breakers
As a component of the Series G Circuit Breakers, the EGB2070FFG has a voltage rating of 600Y/347 VAC, 480 VAC, and 240 VAC for AC applications, along with a 250 VDC rating for DC use. This model has fixed thermal and magnetic trip types with long-time and instantaneous trip functions. It offers inte