Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
As a thermal magnetic circuit breaker, the CH2110 provides effective interruption with a maximum rating of 10 KAIC. This unit functions in a one-phase setting and features LI functionality for both long-time and instantaneous trip conditions. Designed for ease of installation, it uses a plug-in conn
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
This circuit breaker comprises two poles and provides thermal magnetic protection. It supports wire sizes ranging from #14 to #4 AWG and is rated for an interrupt capacity of 10 KAIC. The common trip type allows for simultaneous tripping of both poles during fault conditions.
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
Operating with a nominal discharge current of 20 kA, this surge protection device provides extensive protection with a maximum surge current of 108 kA. The device manages voltages at 150 V L-N and 300 V L-L while securing lines up to 600 V L-N, 1000 V L-L, and 800 V N-G. It is suitable for single-ph
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
Configured specifically as a main lug loadcenter, this model is ideal for single-phase installations. It offers a robust interrupt rating at 25 kAIC and is equipped with copper bus material, ensuring efficient electrical conduction. The loadcenter is designed to house single-pole circuit breakers an
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
This circuit breaker features a single pole configuration and is designed for 1-phase applications. It has a thermal magnetic protection system with long-time and instantaneous trip functions. The unit is rated with an interrupt capacity of 10 KAIC and utilizes a plug-in connection method. The CH fr
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
Rated for 20 amperes, this ground fault circuit breaker utilizes pigtail leads for connections. It features a thermal magnetic protection mechanism and supports both long time and instantaneous trip functions. The interrupting capacity is rated at 10 kAIC at 240 volts, and it accommodates wire sizes
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
This circuit breaker features two poles and a common trip type, offering robust ground fault protection as an equipment protector. With an interrupt rating of 10 kAIC, it ensures reliable performance under fault conditions. The enclosure is rated NEMA 3R, making it suitable for outdoor applications,
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
Featuring two poles, this circuit breaker is utilized for branch circuits and employs thermal magnetic protection strategies. It has a 10 kAIC interrupt rating. This model can accommodate a wire size range of 14 to 6 AWG for both copper and aluminum conductors.
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
This circuit breaker is rated at 15 amps and has an interrupting capacity of 10 kA. It accepts wire sizes between 14 and 8 AWG, and the connection method is bolt-on with lugs. The CHB215 also includes a shunt trip that operates between 120 and 240 volts.
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
This device features a trip unit with long-time and instantaneous functions (LI) and is equipped with a 10 kAIC interrupt rating. It consists of three poles and utilizes box lugs for connections, making it suitable for a variety of mounting scenarios.