408 results
Omron / 3G2
This module operates with an insulation resistance of at least 20 MΩ at 500 VDC and weighs 500 g. It is capable of withstanding shocks of 147 m/s² (15 G) and has a vibration resistance range of 10 to 57 Hz at an amplitude of 0.075 mm. Designed to operate in temperatures from -10°C to 55°C, it can al
Omron / 3G2
The 3G2A5-PS221-E is a power supply designed for versatile applications, accommodating input voltages of 100-120/200-240 VAC. It functions optimally within a voltage range of 85-132/170-264 VAC while supporting a frequency of 50/60 Hz. The power consumption is rated at 150 VA or 55 W maximum. It pro
Omron / 3G2
This link adapter operates within a power supply requirement of 100 to 120 VAC or 200 to 240 VAC, and 12 to 24 VAC/DC. The operating voltage can range between 85 to 132 VAC, 170 to 246 VAC, and 10.2 to 26.4 VAC/DC. This Link Adapter supports auxiliary input for backup power and includes repeater inp
Omron / 3G2
This Omron auxiliary unit is specifically designed for expansion input/output racks. It operates smoothly with Omron C1000, C2000, and C200H programmable controllers. It maintains a standard insulation resistance and is built to endure various conditions, including appropriate temperature and humidi
Omron / 3G2
This model allows for an adjustable frequency range from 0.1 to 400 Hz with a frequency accuracy of ±0.01% digitally and ±0.5% analog. The enclosure type is an open chassis with an IP20 rating, and it operates within an ambient temperature of 14 to 122°F (-10 to +50°C). Equipped with motor overload
Omron / 3G2
This input unit can handle 16 points organized into 2 circuits with 8 points common for flexible configuration. The input current is typically 10 mA at 100 VAC, with a maximum ON voltage of 120 VAC. The OFF voltage is capped at 40 VAC, and it features an ON response time of up to 35 ms and an OFF re
Omron / 3G2
This unit facilitates broadcasting communication over a distance of 500 meters, accommodating up to 32 separate PC link units. It allows for link relay bits ranging from 32 to 512 bits, ensuring ample data transfer capabilities. Diagnostic features include a CPU watchdog timer and CRC transmission e
Omron / 3G2
This inverter model operates efficiently within an input voltage range of 200 to 240 VAC, supporting a power rating of 1.1 kW. It protects against various electrical issues, including overload and short circuit conditions. The output frequency can be adjusted from 0 to 400 Hz, and the inverter maint
Omron / 3G2
This input module features a B-shaped design and has an input impedance of 2.2 kΩ. The typical input current is 16 mA when operating at 12 VDC. The device ensures effective signal detection with a minimum ON voltage of 10.2 VDC and a maximum OFF voltage of 3.0 VDC. Response times are efficient, with
Omron / 3G2
This module supports 32 input points, with a configuration of 8 points per common across 4 circuits. The input current is typically 10 mA at 24 VDC, responding with an ON voltage of 10.2 VDC minimum and an OFF voltage of 3.0 VDC maximum. The unit has a maximum OFF and ON response time of 15 ms. It h