714 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This accessory features LSIG trip functions, providing long-time, short-time, instantaneous, and ground fault protection. It operates at a rated voltage of 600 VAC and covers frequency parameters between 50 Hz and 60 Hz. This model is equipped with true RMS sensing for accurate readings and utilizes
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker accessory features three poles and is designed with a J-K frame type. Its AIC rating is rated at 65 KA at 480 V, ensuring significant fault current handling capability. The humidity tolerance is set at 80% for both operating and storage conditions, making it versatile for variou
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates with voltage ratings of 600 VAC and 250 VDC. It offers interrupting ratings of 65 kAIC at 240 VAC, 35 kAIC at 480 VAC, and 18 kAIC at 600 VAC. The protection is ensured by fixed thermal and magnetic trip units providing long-time and instantaneous (LI) trip functions.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This accessory, suitable for Frame J-K size applications, includes a magnetic trip range of 45 to 150 A. It operates at an AIC rating of 65 kA at 480V and supports a feed-thru connection type. Designed for an environment with humidity levels up to 80% (non-condensing), it is installed at an altitude
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates at a maximum AC voltage of 600 VAC with a feed-thru connection type. It features a K-frame design and is capable of providing magnetic-only protection. Additionally, it has a 35 kA AIC rating at 480 V, ensuring protection against fault currents. It is also suitable for
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The CHLD3600F from Eaton's Series C Circuit Breakers utilizes a sturdy L-Frame design and is rated for a current of 600 Amps. It has three poles and supports a significant interrupting capacity of 65 kAIC at 480VAC. The trip mechanism is based on fixed thermal and fixed magnetic characteristics, ens
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features thermal-magnetic protection and is rated for a system frequency of 50/60 Hz. The FD1025 is designed to interrupt high fault currents, with ratings of 35 kA at 277 V AC and 18 kA at 347 V AC. The connection is established via a feed-through style and advanced load termin
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for right-side mounting, this fixed shunt trip is suitable for L and F frame sizes. It features three poles and has a connection method using pigtail leads. The installation altitude is capped at 1000 meters above sea level, ensuring compatibility with various industrial settings.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker consists of three poles arranged in an F frame size. With a fixed thermal and fixed magnetic trip type, it ensures reliable protection against overloads and short circuits. The interrupt rating is 18 kAIC at 240 VAC and 14 kAIC at 480 VAC, providing substantial fault current sup
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Featuring a trip type designated as T186, this breaker is engineered for reliability. Its L frame size allows for effective circuit protection, and it includes three poles for comprehensive electrical management. With a minimum operating frequency of 50 Hz and a maximum of 60 Hz, it can handle signi