66 results
Honeywell / 7800 Series
This relay control module has a frequency range between 50 Hz and 60 Hz. It is equipped with nonvolatile memory for reliable performance. Users can connect via a Data ControlBus Module or a PC interface. Designed to function in extreme conditions, it has an operational temperature range of -40°C to
Honeywell / 7800 Series
This relay control module is designed for on-off primary control, equipped with prepurge functionality for gas, oil, or dual-fuel single burners. It can handle operating frequencies between 50 Hz and 60 Hz and supports an interrupted pilot type. The unit establishes the pilot flame in either 4 or 10
Honeywell / 7800 Series
This relay control module functions within a frequency range of 50 to 60 Hz. Its application type involves on-off primary control, incorporating a prepurge feature. The module also includes an interrupted pilot design with a 4 to 10-second pilot flame establishing period, while the main flame establ
Honeywell / 7800 Series
This microprocessor-controlled module is lightweight at 3 lbs and features a remarkable operating temperature range from -40°C to 60°C. It also offers storage conditions from -40°C to 66°C. The device maintains functionality in humidity levels up to 85% RH (non-condensing) and supports a maximum pow
Honeywell / 7800 Series
Operated at a voltage of 120 VAC, the RM7838C1004 functions effectively within temperature limits from -40°C to 60°C. It has a plug-in mounting design specifically for wiring subbases Q7800A or Q7800B. Capable of handling a maximum load of 2000 VA, this controller dissipates power up to 10 W and ope
Honeywell / 7800 Series
This control device is characterized by its compact form and efficient operation, supporting a maximum power dissipation of 10 watts. It has an operating temperature range from -40°C to 60°C, while storage temperatures can vary between -40°C and 66°C. The humidity tolerance is up to 85% relative hum
Honeywell / 7800 Series
This control module functions effectively within a temperature range from -40°C to 60°C, ideal for challenging climates. Its maximum total connected load capacity is 2000 VA. The pilot flame is of the interrupted type, with both the main and pilot flame establishing periods set to a duration of 10 s
Honeywell / 7800 Series
This control module, designed for burner operation, features a weight of 4 lbs and can withstand temperatures from -40°C to 60°C during operation. It includes provisions for a quick establishment of both pilot and main flames, with respective establishing periods of 4 or 10 seconds. Suitable for ins
Honeywell / 7800 Series
This burner control unit is rated for operation between temperatures of -40°C and 60°C and can be stored safely from -40°C to 66°C. It supports a maximum humidity range of 85% RH, non-condensing, and allows a total connected load of up to 2000 VA. The device features an initial pilot flame establish
Honeywell / 7800 Series
This control module is capable of operating within a temperature spectrum from -40°C to 60°C. It also maintains functionality in humidity levels up to 85% relative humidity without condensation. The design includes a postpurge timing of 15 seconds and requires a 15A fast blow fuse for safety. The mo