86 results
Eaton Cutler-Hammer / PLCs / BR Circuit Breakers
This circuit breaker features two poles and offers personnel protection against ground faults. It can handle an interrupting capability of 10 kAIC. The neutral connection uses a pigtail style, and the wiring can accommodate sizes from #14 to #4 AWG. Designed for single-phase use, it operates within
Eaton Cutler-Hammer / PLCs / BR Circuit Breakers
Designed for use in demanding environments, the BRX2125 is structured with two poles and includes a thermal magnetic tripping unit. Its interrupt rating reaches 65 kiloamperes at 240 Volts AC, providing substantial fault protection. Additionally, the breaker mounts via a plug-in method and accommoda
Eaton Cutler-Hammer / PLCs / BR Circuit Breakers
This single pole circuit breaker features a trip sensitivity of approximately 30 mA and employs a pigtail neutral connection. The model supports wire sizes ranging from 14 to 8 AWG and can be mounted using a plug-on method. With a UL certification, it has an interrupt rating of 10 kA, ensuring relia
Eaton Cutler-Hammer / PLCs / BR Circuit Breakers
This circuit breaker features two poles and provides an interrupting capacity of 10 kA at 120 Volts AC. It can accommodate conductor sizes ranging from 14 to 4 AWG and utilizes a plug-in connection type, making installation straightforward. The breaker meets compliance standards set by UL and CSA, e
Eaton Cutler-Hammer / PLCs / BR Circuit Breakers
Featuring a common trip design with two poles, the BRN220GF offers an interrupting capacity of 10 kAIC. The breaker is suitable for single-phase applications, with a thermal-magnetic trip mechanism that includes ground fault interruption (GFI) functionality.
Eaton Cutler-Hammer / PLCs / BR Circuit Breakers
As a 2-pole thermal magnetic circuit breaker, the BRX2100 includes a 65 kAIC interrupt rating at 240 V. It is designed for installation with a plug-on mounting type and accommodates wire sizes ranging from 14 AWG to 2/0 AWG. This UL-approved breaker functions at frequencies of 50/60 Hz.
Eaton Cutler-Hammer / PLCs / BR Circuit Breakers
The BR225ST consists of two poles and boasts an interrupt rating of 10 KAIC. The thermal magnetic protection includes both long-time and instantaneous trip functions, ensuring reliable circuit management. A shunt trip is part of the package, adding to its functionality, while the plug-in connection
Eaton Cutler-Hammer / PLCs / BR Circuit Breakers
With a configuration of two poles, this circuit breaker operates effectively in single-phase systems and offers an interrupt rating of 10 KAIC. The device supports both long-time and instantaneous trip functions, ensuring reliable protection against overloads and short circuits. Its plug-in connecti
Eaton Cutler-Hammer / PLCs / BR Circuit Breakers
Designed for use with BR load centers, this thermal-magnetic breaker provides a short-circuit interrupting capacity of 10 kA. The BR340ST operates at a frequency of 60 Hz and accepts conductors ranging from #14 to #4 AWG. Equipped with a common trip mechanism and an included shunt trip device, it fa