109 results
Allen Bradley / Motors / Bulletin 1489
This circuit breaker features a maximum interrupting capacity of 10 kA and has an electrical endurance rating of 6,000 operations. The device has a dual terminal type for convenient connection and is designed for DIN rail mounting. It includes auxiliary, signal, and shunt trip capabilities, enhancin
Allen Bradley / Motors / Bulletin 1489
This circuit breaker is classified with a C trip curve and supports rated currents of 6.0 A. Its interrupting capacity aligns with IEC standards at 15,000 A and meets UL/CSA standards ranging from 10 kA to 14 kA. Designed for DIN rail mounting, it features an IP2x face protection rating.
Allen Bradley / Motors / Bulletin 1489
This bulletin 1489 AC circuit breaker operates at a maximum voltage of 400V AC and is rated for 3.0 A. It features a trip curve of type C and supports a maximum interrupting capacity of 10 kA. The device includes an auxiliary contact, signal contact, and shunt trip capabilities, as well as an IP20 p
Allen Bradley / Motors / Bulletin 1489
The 1489-A1D100 circuit breaker from Allen Bradley features a single-pole configuration with a trip curve rating of D. It is designed for operation at a rated current of 10.0 A and supports a maximum AC voltage of 277 V AC, compliant with UL/CSA standards. With an interrupting rating of 10 kA, it ef
Allen Bradley / Motors / Bulletin 1489
This AC circuit breaker features a trip curve type D and is crafted for safe operation with a protection degree of IP20. It supports mounting on a DIN rail and provides a rated interrupting capacity of 10 kA, suitable for systems operating at 400V AC or 480Y/277V AC. It is designed for up to 6,000 e
Allen Bradley / Motors / Bulletin 1489
This circuit breaker is configured with three poles and operates within a thermal-magnetic protection type. It can handle a voltage rating of 480/277 VAC according to UL/CSA standards and 400 VAC per IEC/EN specifications. The unit functions efficiently in a temperature range, from -25 °C to 55 °C.
Allen Bradley / Motors / Bulletin 1489
This circuit breaker features a three-pole configuration and thermal-magnetic protection for reliable performance. It has a rated interrupt capacity of 10 kA and can function within a frequency range of 50 to 60 Hz. Mounting is facilitated through DIN-rail installation, and it is compatible with wir
Allen Bradley / Motors / Bulletin 1489
This 1-pole circuit breaker features a trip curve type C and is capable of managing voltage ratings of 415 V AC (EN/IEC). It boasts an interrupting rating of 10,000 A, making it suitable for various applications. The breaker accepts wire sizes between #18 and #12 AWG and offers a terminal torque of
Allen Bradley / Motors / Bulletin 1489
The 1489-A1C200 is a circuit breaker designed with a C trip curve, accommodating a maximum interrupting rating of 14,000 A. Compatible with wire sizes ranging from #18 to #12 AWG, this device requires a terminal torque of 21 pounds per inch. The device maintains a power loss of 4.7 watts and has a f
Allen Bradley / Motors / Bulletin 1489
This circuit breaker is a single-pole unit with a rated interrupting capacity of 10 kA. It is designed for mounting on DIN rails and offers an IP20 protection rating. It features auxiliary and signal contacts as well as a shunt trip for added functionality. The unit accommodates a maximum UL/CSA vol