408 results
Omron / 3G2
This unit offers an I/O capacity of 16 inputs and 12 outputs, making it capable of handling diverse control tasks. It communicates via RS-232 and RS-485 interfaces for potential expansions. The controller is designed for operation within a temperature range of 0 to 55°C and features a rapid response
Omron / 3G2
With a robust input frequency range of 50 to 60 Hz and an output frequency range extending to 400 Hz, this inverter caters to various operational needs. The unit is designed to handle an input current of up to 7 Amps and provides an output current of 4.8 Amps. It boasts a significant overload capaci
Omron / 3G2
This inverter operates on a 3-phase AC input of 380-480 V at 50/60 Hz, drawing a current of 6.4 A. It utilizes either vector control or variable frequency control methods. This model includes critical protection mechanisms against overload, overvoltage, undervoltage, overcurrent, and short circuits,
Omron / 3G2
This inverter outputs a voltage range of 0-240V AC in a 3-phase configuration. It operates as an AC drive with input frequencies of 50/60 Hz. The device is capable of handling overloads up to 150% for 60 seconds. It has a fan-cooled design and weighs 2.79 kg, catering to applications requiring effic
Omron / 3G2
This inverter is built for performance, with an apparent power rating of 3.7 kVA and an output current capacity of 4.8 A. The control is managed via V/f control methodology and is equipped with analog and digital input signal interfaces. It features fan-assisted cooling for better thermal management
Omron / 3G2
This Omron CPU rack measures 250 mm tall, 480 mm wide, and 32 mm deep. It operates effectively within a temperature range of 0 to 55°C and can be stored in temperatures from -20 to 65°C. The humidity tolerance range is 35% to 95% relative humidity in non-condensing environments.
Omron / 3G2
This device operates with a power supply input of 24 VDC and is designed for SINK (NPN) input type configurations. The allowed operating temperature ranges between 0 to 55°C, suitable for numerous environments. Weighing 1.450 kg, the 3G2C7-MC223 can be easily mounted on DIN rails, making installatio
Omron / 3G2
This drive features an integrated PID controller and provides a 150% overload capacity for 60 seconds. It can operate with an output voltage of 0 to 240 V and includes options for various field bus modules such as DeviceNet and PROFIBUS. The ambient temperature range for open-air mounting is -10°C t
Omron / 3G2
This RFI filter operates with an input voltage of 3 x 440 VAC in a 3-phase configuration. It is rated for an input frequency of 50-60 Hz and features short-circuit protection for enhanced safety. Capable of functioning at temperatures ranging from -10 to 50°C, it weighs 0.98 kg and provides robust E