714 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This undervoltage release operates within a voltage range of 220–250 VDC and facilitates circuit protection through continuous monitoring. It is intended for use as an internal accessory and mounts on the left side. This unit is equipped with an electromagnetic actuation method and complies with UL
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This device incorporates electromechanical actuation as its trip mechanism and connects via pigtail leads. It is compatible with multiple breaker series, such as JD, JG, and E2J, designed to integrate internally within J-Frame HMCP breakers. This accessory does not include auxiliary contacts for sta
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for three-pole configurations, the KES3400LSG utilizes a solid-state technology trip type known for its reliability. The trip base is RMS 310 compatible, allowing adjustments for long-time, short-time, and ground fault protection. The unit is adjustable for thermal settings and has the capa
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is equipped with two poles and utilizes fixed thermal and magnetic trip units for added protection. It offers impressive interrupting capacities of 200 kAIC at 240 VAC, 100 kAIC at 480 VAC, and 35 kAIC at 600 VAC, ensuring robust fault handling capabilities.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This shunt trip is compatible with a rated operational voltage of 480/600 VAC and rated for 250 A. It operates between 0°C and 40°C for both operation and storage, while ensuring functionality in humidity levels from 5% to 95% (non-condensing). The SNT2P18K model features three poles for effective c
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The EDH2100 breaker's specifications include two poles and a trip type designated T186. It features a robust interrupt rating of 100 kAIC at 240 VAC, making it suitable for high fault current scenarios. The F frame design allows it to operate efficiently within a frequency range of 50 to 60 Hz.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This device integrates two poles and is constructed on the F frame type. The EDH2150 supports operational frequencies ranging from 50 Hz to 60 Hz, ensuring compatibility with different systems. It boasts an impressive interrupt rating of 100 KAIC at 240 VAC, providing reliable protection against fau
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The EHD2025 circuit breaker is compliant for frequencies between 50 Hz and 60 Hz. It can handle an interrupting capacity of 18 KAIC at 240 VAC and 14 KAIC at 480 VAC. It includes a load side terminal type and is constructed in an F frame.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is built on a JK frame type and incorporates a T39 type trip mechanism. It utilizes a 310+ Electronic LSG trip unit and offers solid-state protection, ensuring reliable operation in various applications. Designed to function in environments up to 40°C, the device is suitable for
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The SNT2P06K shunt trip kit is intended for compatibility with three-pole circuit breakers and supports a rated current of 250 A. It functions within control voltage specifications of 48 VDC to 60 VDC. Rated for a wide temperature range, it can operate between -20°C and 70°C and can be stored effect