102 results
Allen Bradley / Motors / Bulletin 1489
The 1489-A1C200 is a circuit breaker designed with a C trip curve, accommodating a maximum interrupting rating of 14,000 A. Compatible with wire sizes ranging from #18 to #12 AWG, this device requires a terminal torque of 21 pounds per inch. The device maintains a power loss of 4.7 watts and has a f
Allen Bradley / Motors / Bulletin 1489
The 1489-D1C020 is part of the Bulletin 1489 series, offering a trip curve classification of C. This circuit breaker supports a frequency range between 50 and 60 Hz. It mounts conveniently on a DIN rail and is rated for shock resistance up to 25 G. Its construction allows for wire sizes from #18 to
Allen Bradley / Motors / Bulletin 1489
This 1-pole circuit breaker features a trip curve type C and is capable of managing voltage ratings of 415 V AC (EN/IEC). It boasts an interrupting rating of 10,000 A, making it suitable for various applications. The breaker accepts wire sizes between #18 and #12 AWG and offers a terminal torque of
Allen Bradley / Motors / Bulletin 1489
This circuit breaker consists of two poles and incorporates auxiliary and signal contacts, as well as a shunt trip feature. With an IP20 protection degree, it is suitable for various applications and mounts easily on DIN rails. The electrical endurance of the device reaches up to 6,000 operations, e
Allen Bradley / Motors / Bulletin 1489
This circuit breaker has an interrupting capacity of 15,000 A as per IEC standards, with a rated interrupting rating of 10,000 A. It operates effectively at a nominal voltage of 277 V AC under UL/CSA standards and includes IP20 front protection, thereby allowing for use in different environmental co
Allen Bradley / Motors / Bulletin 1489
This circuit breaker features a trip curve type D and is suitable for DIN-rail mounting. It can accommodate wire sizes from #18 to #10 AWG and operates within frequency limits of 50 to 60 Hz. The face of the breaker has an IP2x rating, offering protection against access to hazardous parts, while its
Allen Bradley / Motors / Bulletin 1489
This circuit breaker features a trip curve of type C and has an interrupting capacity of 15,000 A, with a rated interrupting capacity of 14,000 A. It offers shock resistance rated at 25 G half-sine wave and includes IP2x face protection for safety. It supports two wires and is designed for DIN rail
Allen Bradley / Motors / Bulletin 1489
This circuit breaker operates at a rated voltage of 415 V AC and is designed with a single pole configuration. It has a shock resistance rating of 25 G and an interrupting capacity of 15,000 A as per IEC standards, as well as a UL/CSA rating of 277 V AC. It mounts securely on DIN rail and provides I
Allen Bradley / Motors / Bulletin 1489
This circuit breaker offers robust protection with a trip curve of type C, making it suitable for various load applications. The unit allows for wire sizes ranging from #18 to #10 AWG and is optimized for installation on DIN rails. It features an IP20 rating for front protection and IP00 rating for
Allen Bradley / Motors / Bulletin 1489
This single-pole circuit breaker is suitable for DIN-rail mounting and features a thermal-magnetic protection mechanism. It operates within a frequency range of 50 to 60 Hz and offers an interrupting capacity of 10 kA. The device follows a trip curve type C for response to overloads.