Honeywell / UDC2800
This model offers control outputs, including a current output rated at 4 to 20 mA or 0 to 20 mA, along with a 5 Amp Form C electromechanical relay. It accepts multiple input types: thermocouple (TC), resistance temperature detector (RTD), millivolt (mV), and various voltage and current signals. The
Honeywell / UDC2800
Compatible with inputs such as TC, RTD, mV, and various voltage and current ranges, this device supports two inputs. Operating within an ambient temperature array of 0 °C to 55 °C, the UDC2800 ensures accurate performance under diverse conditions. Outputs include both current options and an E-M rela
Honeywell / UDC2800
Designed for reliable monitoring, this universal digital controller features two Form C electro-mechanical relay outputs, each rated for 5 Amps. It supports various input types, including TC, RTD, and mV, alongside voltage inputs of 0-5V, 1-5V, and 0-10V. The dynamic controller operates effectively
Honeywell / UDC2800
This controller features a current output option rated between 4 and 20 mA or 0 to 20 mA. It includes a 5 Amp Form C electromechanical relay as Control Output 2, capable of functioning as Alarm 1. It accepts a variety of input signals, including TC, RTD, and several voltage and current ranges. Opera
Honeywell / UDC2800
This universal digital controller supports various input types such as thermocouples (TC), resistance temperature detectors (RTD), and voltage signals of 0-5V, 1-5V, and 0-10V. It is rated for installations up to 2000 meters in elevation, and it operates efficiently across temperatures from 0°C to 5
Honeywell / UDC2800
This digital controller is certified by CE, UL, and CSA, ensuring compliance with international safety standards. It includes 1 auxiliary output, and supports one or two digital inputs for flexibility in communication. The device operates on 100 to 240V AC power and functions optimally in an ambient
Honeywell / UDC2800
This device features dual inputs compatible with TC, RTD, mV, and various voltage and current signal ranges. It includes a 4 to 20mA or 0 to 20mA current output and one alarm relay for effective signaling. Designed for operation in humid conditions, it can withstand a minimum relative humidity of 90
Honeywell / UDC2800
This controller features a current output capability rated at either 4 to 20 mA or 0 to 20 mA, providing flexibility in output choices. It includes one alarm relay for signaling conditions. Input options accommodate TC, RTD, and various voltage levels, ensuring compatibility with multiple sensors. O
Honeywell / UDC2800
Operating within a voltage range of 100 to 240V AC, this digital controller provides current outputs of either 4 to 20 mA or 0 to 20 mA. It includes a form C E-M relay capable of handling 5 Amps. The device supports a variety of input types for comprehensive monitoring, including TC, RTD, millivolt,