507 results
Schneider Electric / PowerPact
The QBP32150TP features a thermal-magnetic trip unit technology with an impressive breaking capacity of 10 kA. It operates effectively at a rated voltage of 240 V and accommodates frequencies from 50 to 60 Hz, making it versatile for different settings.
Schneider Electric / PowerPact
Typically utilizing an operating handle for control, this circuit breaker features a breaking capacity of 25 kA. It also incorporates thermal-magnetic trip technology and can handle a magnetic tripping current of 2400 A. The unit is suitable for use in environments with a minimum frequency of 50 Hz
Schneider Electric / PowerPact
This model includes two poles and operates at a rated voltage of 240 V. Its magnetic tripping current is set at 2400 A, with a hold current of 1200 A. It functions within a frequency range of 50 to 60 Hz, ensuring compatibility with various applications.
Schneider Electric / PowerPact
Designed for operational efficiency, the QDA32175 model supports a rated voltage of 240 V and a breaking capacity of 25 kA. It functions effectively in a frequency range between 50 Hz and 60 Hz. The magnetic tripping current is set at 1800 A, with a magnetic hold current of 1000 A, supporting a cont
Schneider Electric / PowerPact
This circuit breaker operates at a rated voltage of 240 V AC and has a breaking capacity of 65 kA with a code of D. It includes an operating handle for control and supports a network frequency of 50/60 Hz. The device can withstand an impulse voltage of up to 8 kV, ensuring reliable performance under
Schneider Electric / PowerPact
The QGL32175 features a thermal-magnetic trip unit that provides accurate overload and short-circuit protection. With an interrupting capacity of 65 kA at 240 V AC and a breaking capacity code of G, this device is designed to securely manage faults. Mounting is facilitated with unit lugs on both end
Schneider Electric / PowerPact
This circuit breaker operates with a rated voltage of 600 V AC and a substantial breaking capacity of 65 kA. It features an operating handle control type for user convenience, and its design allows for unit mounting on a busbar connection. The circuit breaker is rated for HACR applications, suitable
Schneider Electric / PowerPact
This circuit breaker features three poles and supports frequencies of 50/60 Hz. It boasts a notable breaking capacity of 65 kA and is designed with a thermal-magnetic trip unit. Magnetic tripping occurs at 2400 A, with a holding current of 1200 A, making it a robust solution for fault protection.
Schneider Electric / PowerPact
This circuit breaker features a thermal-magnetic trip technology and operates with 2 poles. It is designed to function effectively in indoor environments with no exposure to corrosive elements. The operating temperature range extends from 0 to 40 degrees Celsius, and it allows for 80% relative humid