408 results
Omron / 3G2
This inverter operates with a maximum power output of 7.5 kW and a frequency range of 0.1 to 400 Hz. Weighing 4.8 kg, it employs fan cooling to maintain optimal performance. The inverter provides sinusoidal PWM control and supports switchable voltage vector and v/f control modes. It is precise, with
Omron / 3G2
This module features up to 32 points, arranged as 8 points per common with 4 separate circuits. The response times are precisely calibrated, with both ON and OFF timing capped at a maximum of 1.5 ms. Typical input current is rated at 10 mA when supplied with 24 VDC, ensuring efficient power use duri
Omron / 3G2
This teaching box operates on a compatible voltage range in SYSMAC C500 power inputs. It accepts manual teaching inputs, enabling efficient operation. Closed-loop feedback is achieved through an encoder or similar mechanism. It conveniently fits into a slot within the SYSMAC C500 rack, supporting te
Omron / 3G2
Designed for efficient signal handling, this module accommodates two analog inputs with a working range of -10 to +10 VDC. It features a resolution of 1/4095, providing detailed measurements with 12-bit binary output. The device operates with a maximum power consumption of 500 mA at 5 VDC.
Omron / 3G2
This drive has an output current rating of 3 Amps and operates within a frequency range of 0.5 to 400 Hz. It utilizes V/f control for effective motor performance. The 3G3EV-A2004M-E is rated IP20 for ingress protection and provides an overload capacity of 120 percent. Its ambient temperature range f
Omron / 3G2
This model is an I/O expansion unit compatible with the C500 PC series. It requires the Interface I/O unit to be mounted on the Expansion I/O Module. It supports power supply options of either 100 to 120/200 to 240 VAC or 24 VDC. With a weight of just 0.35 kg, the unit facilitates easy installation
Omron / 3G2
This controller maintains functionality within an ambient temperature range of 0 to 50°C and can be stored at temperatures between -20 to 65°C. It offers humidity tolerance from 35 to 80% relative humidity in non-condensing environments, ensuring reliable operation under various conditions. The devi
Omron / 3G2
This drive supports an ambient temperature range of 14 to 122°F (-10 to +50°C). It has a maximum output voltage of 200 to 230 V for 3-phase systems and can be programmed to output frequencies up to 400 Hz. Frequency settings can be adjusted with a resolution of 0.01 Hz for low ranges and 1 Hz for hi
Omron / 3G2
This AC drive supports a wide output voltage range of 0 to 460 volts AC and can deliver an output current of 3.4 amps. Its output power rating of 2.6 KVA reflects its robust capabilities. The unit's efficiency ranges from 95% to 98%, ensuring high performance while minimizing energy loss during oper
Omron / 3G2
With a resolution of 1/4095 across the full scale, this unit is equipped with a 12-bit binary representation for PC signals. The analog input module provides two dedicated input channels. Its external connections are made via a 17-pin terminal block, which is non-removable. Power consumption is capp