109 results
Allen Bradley / Motors / Bulletin 1489
This circuit breaker features a trip curve type D and is suitable for DIN-rail mounting. It can accommodate wire sizes from #18 to #10 AWG and operates within frequency limits of 50 to 60 Hz. The face of the breaker has an IP2x rating, offering protection against access to hazardous parts, while its
Allen Bradley / Motors / Bulletin 1489
This circuit breaker can handle a maximum voltage of 277 V AC per UL/CSA standards and 415 V AC according to EN/IEC standards. It features an IP20 front-protection rating. Additionally, it supports a frequency range from 50 to 60 Hz and accommodates wire sizes between #18 and #10 AWG, with a strip l
Allen Bradley / Motors / Bulletin 1489
This circuit breaker is a three-pole design with a rated current of 5A. It supports operational frequencies of 50/60 Hz. With an impulse withstand voltage rating of 4 kV and a minimum operating temperature of -25 °C, it is suitable for various applications. The enclosure has an IP40 rating internall
Allen Bradley / Motors / Bulletin 1489
Configured with three poles, this circuit breaker has a D curve trip characteristic and is suitable for wiring from 18 AWG to 8 AWG. It is designed for a DIN rail mounting solution and has an interrupt rating of 10 kA. The operating temperature range is between 0 and 40 degrees Celsius.
Allen Bradley / Motors / Bulletin 1489
This 3-pole circuit breaker features a trip curve of Curve C, ensuring quick response for moderate overloads. It can handle input frequencies from 50 Hz to 60 Hz, along with a rated short-circuit breaking capacity of 15 kA. Additionally, it supports impulse voltage up to 4 kV and is rated at IP20 fo
Allen Bradley / Motors / Bulletin 1489
This circuit breaker offers robust protection with a trip curve of type C, making it suitable for various load applications. The unit allows for wire sizes ranging from #18 to #10 AWG and is optimized for installation on DIN rails. It features an IP20 rating for front protection and IP00 rating for
Allen Bradley / Motors / Bulletin 1489
This circuit breaker features a trip curve of type D and supports a minimum frequency of 50 Hz, up to a maximum of 60 Hz. It is rated for a maximum voltage of 415 V AC in accordance with EN/IEC standards. The device is compatible with two wires ranging in size from #18 to #10 AWG and can be mounted
Allen Bradley / Motors / Bulletin 1489
This 3-pole circuit breaker operates at a rated current of 6.0 A with a D trip curve. It is designed for use at a rated voltage of 415 V AC and can handle interrupting capacities designed for both IEC requirements at 15,000 A and UL/CSA standards ranging from 10 kA to 14 kA. Its dimensions fit DIN r
Allen Bradley / Motors / Bulletin 1489
Designed for use in a variety of electrical applications, this circuit breaker features two poles and an interrupting rating of 14 kA for reliable operation. It has a trip curve type classified as Curve D, making it suitable for specific load conditions. The chassis is ideal for DIN-rail mounting an
Allen Bradley / Motors / Bulletin 1489
Providing excellent protection, the 1489-A3C005 circuit breaker has a rated voltage of 480Y/277 V AC and can handle a maximum interrupting rating of 10 kA. This device is compatible with wire sizes ranging from #18 to AWG6 and provides a front protection rating of IP20.