714 results
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a three-pole configuration and is rated for three-phase applications. Its interrupting capacity is rated at 65 kAIC for 240 VAC, 35 kAIC at 480 VAC, 25 kAIC at 600 VAC, and 22 kAIC at 250 VDC. The breaker incorporates both fixed thermal and magnetic trip units.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This two-pole circuit breaker has a K-frame and responds to 50/60 Hz frequency ratings. Its interrupting capacity is rated at 65 kAIC for 240 Vac and 10 kAIC at 250 Vdc, providing effective protection against overloads. This device is UL Listed for enhanced safety standards.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates on a two-pole system and is encased in durable glass polyester material. It features a frequency rating of 50/60 Hz and a trip type identified as T186. The device meets stringent safety certifications, being UL Listed, thereby ensuring its reliability in various electri
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This breaker operates at voltages up to 600 VAC for AC applications and 250 VDC for DC applications. It utilizes fixed thermal and magnetic trip mechanisms for reliable protection. Interrupting capacity is rated at 65 KAIC at 240 VAC and 35 KAIC at 480 VAC, ensuring effective circuit protection unde
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This K-frame designed unit includes two poles and can manage various interrupting ratings: 10 kAIC at 250 VDC, 65 kAIC at 240 VAC, 35 kAIC at 480 VAC, and 25 kAIC at 600 VAC. The trip mechanism is a combination of fixed thermal and fixed magnetic types, allowing it to effectively identify overload c
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates at 240 VAC and 125 VDC, with an interrupting capacity of 65 kAIC for fault protection. Designed as a thermal magnetic trip unit, it features a robust F frame type construction. The ED3030 functions effectively with a frequency range of 50 to 60 Hz.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This single-pole circuit breaker features a frame size designated as Frame G. It has a surface mounting style and operates at frequencies of 50/60 Hz. The trip type is T186, and it provides an interrupting capacity of 14 kAIC at 277 Vac. Its design is optimized for single-phase use, with a maximum t
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features two poles and provides an interrupting capacity of 100 kAIC at 240 VAC and 65 kAIC at 480 VAC. With a trip type of fixed thermal and fixed magnetic, it delivers effective protection functions categorized as LI (Long-Time and Instantaneous). Operating frequency ranges fr
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is designed for use in three-phase systems and has fixed thermal and magnetic trip types for effective protection. It features interrupting ratings of up to 65 kAIC at 240 VAC and 14 kAIC at both 480 VAC and 250 VDC, providing reliable fault interruption capabilities. Operating
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is of the GDB Type and features a G-frame form factor. It consists of three poles and operates within frequencies ranging from 50 Hz to 60 Hz. The breaker provides significant interrupting capacity, rated at 14 kAIC for 480 volts and 65 kAIC for 240 volts, ensuring reliable circ