Honeywell / 7800 Series
This programming burner control unit operates within a frequency range of 50 to 60 Hz. It can handle a maximum connected load of 2000 VA. The module establishes a pilot flame in a timeframe of 4 to 10 seconds, while the main flame takes between 10 to 15 seconds. It functions optimally within a tempe
Honeywell / 7800 Series
Designed to reliably establish flame, this device can handle a maximum connected load of 2000 VA. It features a 10-second flame establishment period and operates efficiently in temperatures ranging from -40°C to 60°C. The unit supports a maximum humidity of 85% RH without condensation, ensuring depe
Honeywell / 7800 Series
With an input voltage frequency range of 50/60 Hz, the unit is built to function effectively within a temperature range from -40°C to 60°C. Designed to endure diverse conditions, it can handle a humidity level of up to 85% RH without condensation. It has a power dissipation limit of 10 W and can sup
Honeywell / 7800 Series
This diagnostic tester supports an input voltage frequency of 50/60 Hz. It works within a temperature range from -18°C to 49°C during operation, while it can withstand storage conditions between -34.5°C and 65°C. The unit dissipates 20 watts of power and includes a 1.0A (3AG) fuse for protection. It
Honeywell / 7800 Series
This control unit offers a maximum power dissipation of 10 W and supports a total connected load of up to 2000 VA. It is equipped with fast-blow fusing rated at 15A maximum. The burner control can establish a pilot flame within a span of 4 to 10 seconds. The main flame requires an establishment time
Honeywell / 7800 Series
This burner control unit supports a minimum operating temperature of -40°C, making it ideal for harsh conditions. It can function at temperatures up to 60°C and has a maximum humidity tolerance of 85% RH (non-condensing). With a rated power dissipation of 10 W maximum and a maximum total connected l
Honeywell / 7800 Series
This model features a main flame establishing period adjustable to 10, 15, or 30 seconds, and can also operate intermittently. It withstands temperatures from -40°C to 60°C during operation and has a storage temperature range of -40°C to 66°C. This burner control unit can handle a maximum connected
Honeywell / 7800 Series
This burner control module is compatible with a Q7800A2005/Q7800B2003 wiring subbase and is designed for easy plug-in installation. It has a rated maximum of 2000 VA for total connected load and operates within a temperature range of -40°C to 60°C. Built to meet environmental challenges, it performs
Honeywell / 7800 Series
Designed for robust performance, this burner control module has a temperature range that spans from a minimum of -40°C to a maximum of 60°C during operation, while storage temperatures can range from -40°C to 66°C. With a humidity tolerance of 85% RH (non-condensing), it supports a maximum connected
Honeywell / 7800 Series
This module is built to endure extreme temperatures, functioning between -40°C and 60°C, while also remaining effective in storage conditions from -40°C to 66°C. It features a notable humidity tolerance of 85% RH without condensation, and it can handle a maximum connected load of 2000 VA. It mounts