Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This motor circuit protector features three poles and a magnetic trip range between 750 and 2500 A, ensuring reliable operation under various load conditions. Its mountable design allows for easy panel installation and it supports feed-thru connections. Additionally, this unit is rated for an interr
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This model operates effectively at 480Y/277 VAC and 125/250 VDC. It boasts an interrupting capacity of 65 kAIC at 240 VAC and 14 kAIC at 480Y/277 VAC, ensuring it can handle significant fault currents. The circuit breaker supports a frequency range from 50 Hz to 60 Hz and utilizes a long-time and in
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker is designed with three poles, facilitating the distribution of power in three-phase systems. The thermal magnetic trip mechanism enhances its ability to respond promptly to overload conditions. It boasts interrupting ratings of 25 kAIC at 240 V and 18 kAIC at 480 VAC, confirming
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker operates at voltage ratings of 600 VAC for AC systems and 250 VDC for DC applications. Designed with fixed thermal and magnetic trip types, it can interrupt high fault currents with ratings of 65 kAIC at 240V AC, 35 kAIC at 480V AC, and 25 kAIC at 600V AC. Its frame size is cate
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This accessory operates effectively within -20 °C to 70 °C during use, and it can withstand storage conditions from -40 °C to 85 °C. Designed for installation at altitudes up to 2000 meters, it also performs in relative humidity levels ranging from 5% to 95% (non-condensing).
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This HFD-DC type circuit breaker has a frame classified as F Frame and operates with three poles. It can withstand interrupt currents of 65 kAIC at 480 VAC and 42 kAIC at 600 VAC. The trip mechanism is fixed thermal and magnetic, ensuring effective overcurrent protection at operating frequencies ran
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features an F frame design and includes line and load terminals. It is engineered to handle electrode frequencies from 50 Hz to 60 Hz. The unit's interrupting capacity stands at 18 kAIC for 240 VAC and 14 kAIC for 480 VAC. Additionally, it employs a fixed thermal and magnetic tr
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features a unique solenoid-operated design that allows for remote control functionality. It supports dual poles and accommodates wire sizes from #14 to #8 AWG for copper and #12 to #8 AWG for aluminum. The breaker has an interrupt rating of 14 kAIC at 240 V and is identified by
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed for three-phase applications, the HFD3020 features a thermal magnetic trip unit with a LI trip function that allows for both long-time and instantaneous trip settings. It is capable of interrupting currents with a capacity of 100 kAIC at 240 VAC and 65 kAIC at 480 VAC, ensuring reliable pro
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker accessory operates effectively at a rated voltage of up to 600 VAC for AC applications, and 125 VDC and 250 VDC for DC applications. The minimum operational temperature is -20 °C with a maximum of 70 °C. For storage, it can withstand temperatures ranging from -40 °C to 80 °C, co