74 results
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
This circuit breaker includes three poles and has a notable interrupting capacity of 10 kAIC at 240 VAC. It operates effectively in environments with relative humidity from 5% to 95% (non-condensing) and weighs only 0.9 lbs, making it a compact and efficient solution for circuit protection.
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
This Type CL circuit breaker is designed as a 1-Inch classified replacement. It has a 10 kAIC interrupting rating and utilizes thermal-magnetic technology for reliable operation. The plug-on mounting style simplifies installation, making it ideal for single-phase applications.
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
The CL250 circuit breaker operates under both 50 Hz and 60 Hz frequencies. With an interrupting capacity rated at 10 kAIC, this device ensures reliable circuit protection. The mounting style is plug-on, allowing for convenient installation, and it accommodates wire sizes from #14 to #4 AWG.
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
This thermal-magnetic circuit breaker is built with two poles, capable of handling a rated current of 45 A. It operates efficiently within a voltage range of 120/240 VAC, providing significant interrupt capacity at 10 kAIC. Designed with a thermal-magnetic trip unit, it offers long-time delay and in
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
This component operates effectively in environments with temperatures ranging from -30 °C to 60 °C. It is designed to function with relative humidity levels between 5% and 95%, provided they are non-condensing. The hub style is designated as H2, and the unit can be installed at altitudes up to 2000
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
The CHF225 circuit breaker features a 10 kAIC interrupting rating, making it capable of handling high fault currents effectively. It mounts with a plug-on design and employs heavy-duty lug terminals for robust connections. It accepts wire sizes ranging from #14 to #8 AWG and includes a common trip m
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
This unit includes a single pole and a neutral connection in the form of a pigtail. It utilizes thermal-magnetic trip unit technology to enhance safety. The interrupting rating is capped at 10 kAIC, ensuring reliable performance under fault conditions. Operating temperatures range from -35°C to 66°C
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
This power distribution block handles a voltage range of 600 VAC and 600 VDC. It accommodates primary wire sizes from 2/0 AWG to 8 AWG and secondary wire sizes from 4 AWG to 14 AWG. Built with a phenolic body for durability, the unit requires panel mounting for installation and is designed for use i
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
This circuit breaker utilizes a thermal-magnetic trip mechanism and is suitable for two-pole installations. It is designed to connect using a plug-on clip and features screw lug terminals for secure wiring. It accommodates wire sizes ranging from #14 to #4 AWG, making it adaptable for different appl
Eaton Cutler-Hammer / PLCs / CH Loadcenters and Circuit Breakers
This circuit breaker is rated for a maximum interrupting capacity of 10 kAIC at 120/240 V. It is a single-pole device configured for 1 phase applications. Operating temperature ranges span from -35°C to 66°C, with the ability to function effectively in relative humidity levels from 0 to 95% without