Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker features three poles and is intended for three-phase applications. It utilizes an Electronic Digitrip 310 RMS trip unit that supports LSI trip functions: Long-Time, Short-Time, and Instantaneous. The breaker has impressive interrupt ratings: 100 kAIC at 240 VAC, 65 kAIC at 480 V
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This 3-pole circuit breaker operates in a three-phase system and supports an AC voltage rating of up to 600V. With a weight of 11.5 lbs, this model is designed for reliability under various load conditions. The interrupting capacities include 100 kAIC at 240 VAC, 65 kAIC at 480 VAC, and 35 kAIC at 6
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This circuit breaker showcases a voltage rating of 600V AC and 250V DC. With an interrupting capacity of 65 kAIC at 240 VAC, 35 kAIC at 480 VAC, and 18 kAIC at 600 VAC, it ensures robust performance during fault conditions. The device supports long-time, short-time, and ground fault trip functions,
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This device includes three poles and is suitable for three-phase systems. Its magnetic trip range spans from 1750 A to 3500 A, providing robust protection against overloads. The product fits a NEMA Size 5 starter and functions effectively in relative humidity levels from 5% to 95% (non-condensing).
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This motor circuit protector is rated for 100 A and accommodates three poles for operational versatility. It can handle a maximum voltage of 600 V AC and has a voltage rating of 250 VDC. The magnetic trip range spans from 300 A to 1000 A, ensuring instantaneous protection. It also includes an auxili
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Engineered as a two-pole circuit breaker, this unit features a trip type classified as T186. It boasts an interrupt capability of 42 kAIC at 600 Vac, ensuring robust fault protection. Since it can handle a temperature rating of up to 40 degrees Celsius, it is equipped for diverse operational environ
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This molded case switch features three poles and is rated for 150 A of current. It boasts interrupting ratings of 65 kAIC at 240 VAC and 35 kAIC at 480 VAC, ensuring it can handle significant fault currents. The unit includes fixed thermal and magnetic trip mechanisms for reliable protection.
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
Designed with three poles, the HFD3090L can manage substantial electrical loads. It has an interrupting capacity of 100 kAIC at 240 VAC and 65 kAIC at 480 VAC, making it suitable for high-demand environments. Fixed thermal and magnetic trip types provide reliable overload and short-circuit protectio
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
The UVH2LP03K mechanism is intended for left-pole mounting and features a connection type that includes 18-inch pigtail leads. Its operating temperature specifications range from -20°C to 60°C, while it can be stored at temperatures from -30°C to 70°C. This unit operates effectively within a relativ
Eaton Cutler-Hammer / PLCs / Series C Circuit Breakers
This shunt trip device possesses a weight of just 1 lb and is specifically intended for left pole mounting. It utilizes pigtail leads for connections and functions within a temperature range of -25°C to 70°C. Additionally, it can be stored in environments ranging from -30°C to 80°C and tolerates rel