Schneider Electric / TeSys
This contactor from the TeSys series operates at a power level of 132 kW at 400 V and supports voltages up to 600 V AC. It is designed for a control voltage of 120 V AC and operates efficiently across temperatures ranging from -5 °C to 55 °C. Designed for versatility, this contactor can handle up to
Schneider Electric / TeSys
This contactor features three poles and supports both resistive loads as well as motor control operations, with a rated current of 80 A for resistive loads and 125 A for motors. The control circuit requires a voltage of 230V AC and is classified under overvoltage category III. With a pollution degre
Schneider Electric / TeSys
With a robust mechanical endurance of 5 million cycles, this unit can handle high operational demands. It boasts a de-energizing response time between 130 and 230 ms, while the energizing response time ranges from 40 to 80 ms. The coil's inductance measures at 2.3 H, with a resistance of 60.9 Ω duri
Schneider Electric / TeSys
This contactor is equipped with three poles and features three Normally-Open contacts. It delivers an operating current of 185 Amperes at 55°C and can reach 275 Amperes at 40°C. The output power rating spans from 55 to 110 kilowatts. It is suitable for installation in a non-condensing environment, w
Schneider Electric / TeSys
The GV7RS150 motor circuit breaker can handle an impressive breaking capacity of up to 100 kA. It functions in AC networks, supporting frequencies of 50/60 Hz. It has a conventional free air thermal current rating of 150 A and dissipates 8.7 W of power per pole. The GV7RS150 can be mounted verticall
Schneider Electric / TeSys
The LC1F1504 four-pole contactor consists of 4 normally open (NO) contacts and can handle a control circuit voltage ranging from 24 to 575 V. With a rated insulation voltage of 1500 V and an impressive impulse withstand rating of 8 kV, it ensures reliable performance. It can also sustain a conventio
Schneider Electric / TeSys
Operable up to 690 V AC at 50/60 Hz, this motor starter has a rated insulation voltage of 690 VAC. It uses a rotary handle for control and supports motor power ratings of 1.1 kW at 400/415 V AC, 1.5 kW at 500 V AC, and 2.2 kW at 690 V AC. The device features a breaking capacity of 100kA for voltages
Schneider Electric / TeSys
Designed with a contact configuration of 2 normally open (NO) and 2 normally closed (NC) contacts, this 4-pole contactor operates effectively within a frequency range of 25 to 400 Hz. It has a maximum operating voltage of 690 V AC or 300 V DC, making it suitable for various industrial control enviro
Schneider Electric / TeSys
The LC1F1154 features a 4-pole configuration with 4 normally open contacts (4 NO). The unit supports panel or DIN rail mounting options and has an IP2X rated enclosure. Suitable for applications with a rated voltage of 600 V AC, this contactor also has an insulation voltage of 1000 V, making it idea
Schneider Electric / TeSys
This current transformer offers a maximum conductor aperture of 35 mm and supports cable sections up to 30 mm². The device operates efficiently within a temperature range of up to 50 °C and features a robust insulation rating of 690 V (UI). It has a compact form factor with dimensions of 107 mm in h