1305-BA02A-HAP

Revisions: Ser A 
Description: The Allen-Bradley 1305-BAO2A-HAP is part of the 1305 AC Drive series designed with IP 30/NEMA Type 1 enclosures, Three-phase rating, 380-460V Operating Voltage and a Programmer Only English language interface.
Available Now
Request a quote for 1305-BA02A-HAP

Description: The Allen-Bradley 1305-BAO2A-HAP is part of the 1305 AC Drive series designed with IP 30/NEMA Type 1 enclosures, Three-phase rating, 380-460V Operating Voltage and a Programmer Only English language interface.

top legal disclaimer
disclaimer
credit cards
better business bureau
Revisions: Ser A 

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 1305-BA02A-HAP.
Exchange: Exchange credit for your defective unit available.

To speak to a sales representative for pricing & lead time:

phone

International
919-205-4392
phone

International
919-205-4392

Rated 4 with 27 reviews

    Technical Specifications for 1305-BA02A-HAP

ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1305-BA02A-HAP
Product Line1305 AC Drives
Enclosure TypeIP 30 (NEMA Type 1)
Voltage380-460V, Three Phase
Human Interface ModulesProgrammer Only
LanguageEnglish
Horsepower.75 HP
Motor Rating (kW, Output Current).55 kW 1.8 A
Product Lifecycle Status*Discontinued/Obsolete

*The Allen Bradley 1305-BA02A-HAP has been discontinued by the manufacturer, however we specialize in obsolete parts and can likely still supply surplus and/or refurbished replacement 1305-BA02A-HAP units instead of migration.

ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1305-BA02A-HAP
Product Line1305 AC Drives
Enclosure TypeIP 30 (NEMA Type 1)
Voltage380-460V, Three Phase
Human Interface ModulesProgrammer Only
LanguageEnglish
Horsepower.75 HP
Motor Rating (kW, Output Current).55 kW 1.8 A
Product Lifecycle Status*Discontinued/Obsolete

*The Allen Bradley 1305-BA02A-HAP has been discontinued by the manufacturer, however we specialize in obsolete parts and can likely still supply surplus and/or refurbished replacement 1305-BA02A-HAP units instead of migration.

s

About 1305-BA02A-HAP

The 1305-BA02A-HAP 3-phase AC Drive, manufactured by Allen Bradley, does not come with a speed-sensitive surplus guard, thermal memory retention or terms to act upon motor over-temperature sensing. If this type of protection is warranted, it must be provided by additional parts or means.

The 1305-BA02A-HAP drive is built to withstand most of the internally generated intervention and, most of the times, no additional precautions are needed outside of those mentioned in the unit’s manual during the installation process. Because the 1305-BA02A-HAP DC drive can generate severe electrical transient, the coils of DC energized contactors allied with drives should be controlled and contained with the help of some diode or similar device so as to prevent any possible casualty. Due to its potentially harmful nature, in case of using in areas with frequent lightning, additional preventive measures must be implied.

The 1305-BA02A-HAP drive is well suited for connections with the correct voltage (380 to 460 Volts), single or three phase AC power line, but there remains the slim possibility of a power input drive malfunction due to the power line faulting. However, the danger can be alleviated with the introduction of a line reactor or isolation type transformer that has a 3% drive input impudence. On the contrary, before introducing any of the said transformers or malfunction reduction tools the user should determine if any such measures are actually necessary. Some cases where this might be true are first if the module’s AC line has power factor alteration capacitors containing in and out switching systems, then having an AC line reactor or isolation type transformer between the capacitor and input drive may be necessary. Secondly, if the AC line is experiencing recurring temporary power disruption or high voltage spikes, then it may require an AC line reactor or isolation type transformer to stabilize. In both cases, the drives are at risk of minimal damage due to the change of voltage and equipment.

This module’s enclosure type is the IP 30 NEMA Type 1 enclosure. It has a .55 kW motor rating with 1.8 Amperes, a .75 Horsepower, and its HIM (Human Interface Module) is “Programmer-Only”.

Repair Services for 1305-BA02A-HAP

Type Lead Time Price Action
Repair Service 2-4 weeks $671.99cartAdd to Cart

Our highly skilled technicians can repair your 1305-BA02A-HAP. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions for 1305-BA02A-HAP

Please refer to the manual for more information about the 1305-BA02A-HAP such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
1305-BA02A-HAP Ser A
1305-BA02A-HAP/A, Series A, Rev A Request Quote
Common misspellings:
  • l305-BA02A-HAP
  • 13o5-BA02A-HAP
  • 1305-8A02A-HAP
  • 1305-BAo2A-HAP
  • 1305BA02AHAP

Dimensions For 1305-BA02A-HAP

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For 1305-BA02A-HAP

Width 6-11/16 in. (170 mm)
Height 7-11/16 in. (195 mm)
Depth w/o Pot. 7-1/4 in. (179 mm)
Depth w/ Pot. 7-1/4 in. (184.1 mm)
Weight 8.0 lb (3.6 kg)

Resolutions For 1305-BA02A-HAP

Technical Specifications
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1305-BA02A-HAP
Product Line1305 AC Drives
Enclosure TypeIP 30 (NEMA Type 1)
Voltage380-460V, Three Phase
Human Interface ModulesProgrammer Only
LanguageEnglish
Horsepower.75 HP
Motor Rating (kW, Output Current).55 kW 1.8 A
Product Lifecycle Status*Discontinued/Obsolete
ManufacturerRockwell Automation
BrandAllen-Bradley
Part Number/Catalog No.1305-BA02A-HAP
Product Line1305 AC Drives
Enclosure TypeIP 30 (NEMA Type 1)
Voltage380-460V, Three Phase
Human Interface ModulesProgrammer Only
LanguageEnglish
Horsepower.75 HP
Motor Rating (kW, Output Current).55 kW 1.8 A
Product Lifecycle Status*Discontinued/Obsolete

*The Allen Bradley 1305-BA02A-HAP has been discontinued by the manufacturer, however we specialize in obsolete parts and can likely still supply surplus and/or refurbished replacement 1305-BA02A-HAP units instead of migration.

About

The 1305-BA02A-HAP 3-phase AC Drive, manufactured by Allen Bradley, does not come with a speed-sensitive surplus guard, thermal memory retention or terms to act upon motor over-temperature sensing. If this type of protection is warranted, it must be provided by additional parts or means.

The 1305-BA02A-HAP drive is built to withstand most of the internally generated intervention and, most of the times, no additional precautions are needed outside of those mentioned in the unit’s manual during the installation process. Because the 1305-BA02A-HAP DC drive can generate severe electrical transient, the coils of DC energized contactors allied with drives should be controlled and contained with the help of some diode or similar device so as to prevent any possible casualty. Due to its potentially harmful nature, in case of using in areas with frequent lightning, additional preventive measures must be implied.

The 1305-BA02A-HAP drive is well suited for connections with the correct voltage (380 to 460 Volts), single or three phase AC power line, but there remains the slim possibility of a power input drive malfunction due to the power line faulting. However, the danger can be alleviated with the introduction of a line reactor or isolation type transformer that has a 3% drive input impudence. On the contrary, before introducing any of the said transformers or malfunction reduction tools the user should determine if any such measures are actually necessary. Some cases where this might be true are first if the module’s AC line has power factor alteration capacitors containing in and out switching systems, then having an AC line reactor or isolation type transformer between the capacitor and input drive may be necessary. Secondly, if the AC line is experiencing recurring temporary power disruption or high voltage spikes, then it may require an AC line reactor or isolation type transformer to stabilize. In both cases, the drives are at risk of minimal damage due to the change of voltage and equipment.

This module’s enclosure type is the IP 30 NEMA Type 1 enclosure. It has a .55 kW motor rating with 1.8 Amperes, a .75 Horsepower, and its HIM (Human Interface Module) is “Programmer-Only”.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks $671.99cartAdd to Cart

Our highly skilled technicians can repair your 1305-BA02A-HAP. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks $671.99cartAdd to Cart

Our highly skilled technicians can repair your 1305-BA02A-HAP. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions

Please refer to the manual for more information about the 1305-BA02A-HAP such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
1305-BA02A-HAP Ser A
1305-BA02A-HAP/A, Series A, Rev A Request Quote

Common misspellings:
  • l305-BA02A-HAP
  • 13o5-BA02A-HAP
  • 1305-8A02A-HAP
  • 1305-BAo2A-HAP
  • 1305BA02AHAP
PDF
Dimensions

Dimensions For 1305-BA02A-HAP

Width 6-11/16 in. (170 mm)
Height 7-11/16 in. (195 mm)
Depth w/o Pot. 7-1/4 in. (179 mm)
Depth w/ Pot. 7-1/4 in. (184.1 mm)
Weight 8.0 lb (3.6 kg)