The 1305 Adjustable Frequency AC Drive is a variable speed drive designed to control the speed of three-phase AC induction motors in a variety of demanding applications where flexibility, performance and ease of use are essential. The 1305 Adjustable Frequency AC drive is available with ratings 0.37 to 4 kW (0.5 to 5HP) at 380-460V and 0.37to 2.2 kW (0.5 to 3HP) at 200-230V.

Not an Authorized Distributor: DO Supply is not an authorized distributor for listed manufacturers or tradenames and therefore the manufacturer's warranty does not apply. All of our products come with DO Supply's 2-year warranty.
Learn more

Browse 1305 AC Drives

Browse available units in our catalog of 1305 AC Drives.

1305-BA04A-IT-HAP

This device supports three-phase electrical systems, offering an operating temperature tolerance between 0 °C and 50 °C. Its non-condensing humidity range is acceptable up to 95%, while the device can

In Stock Ships Tomorrow
5.0

1305-BA06A-DE-HAP

This model features a dedicated program-only Human Interface Module (HIM). It maintains operational efficiency within a temperature range from 0 °C to 50 °C and can withstand storage temperatures betw

In Stock Ships Today
5.0

1305-BA06A-ES-HAP

Capable of operating within a temperature range of 0 °C to 50 °C, the unit is suitable for a variety of environments. It has an internal cooling method that relies on natural convection and has a curr

In Stock Ships Today
5.0

1305-BA06A-FR-HA2

Operating with a temperature range from 0 °C to 50 °C, this drive is suitable for a variety of environments. In storage, it can withstand temperatures as low as -40 °C and as high as 70 °C. This unit

In Stock Ships Today
5.0

1305-BA09A-DE-HA1

This module delivers output voltage adjustable from 0 to 460 VAC and can handle an output frequency ranging from 0 to 400 Hz. Its enclosure meets the IP30 (NEMA 1) rating for internal applications. Eq

In Stock Ships Today
5.0

1305-BA09A-DE-HA2

This unit provides a control method utilizing a V/Hz (Volts per Hertz) scalar, ensuring stable operation across its rated input voltage range of 380-460 V AC. It offers an overload capability that all

In Stock Ships Today
5.0

1305-BA09A-DE-HAP

Designed for flexible applications, this drive adjusts the output frequency from 0 to 400 Hz. It operates efficiently with an output current of 9 A and offers an input voltage range of 380 to 460 V AC

In Stock Ships Today
5.0

1305-BA09A-ES-HA1

This drive supports 50/60 Hz input frequency and has an input current of 8.7A. The output voltage spans from 0 to 460 VAC, with an output current of up to 9.0A at 380V. The unit utilizes a Volts-per-H

In Stock Ships Today
5.0

1305-BA09A-FR-HA2

This AC drive offers adjustable output voltage from 0 volts to the configured input voltage. Output frequencies can be adjusted up to 400 Hz, making it suitable for various applications. The device is

In Stock Ships Today
5.0

1305-BA09A-HA2-IT

Designed for efficient motor control, this drive operates with an input voltage of 380 to 460 volts AC, with a maximum output frequency of 400 Hz. It has a typical efficiency rating of 97.5% and is en

In Stock Ships Today
5.0
Showing 101-110 of 133 results

About 1305 AC Drives

Designed and built by Allen-Bradley, the 1305 AC drives are variable speed drives and they are designed for ensuring control of 3-phase induction motors. The 1305 AC drives are built to provide immunity to most externally generated interference. The coils of DC energized contactors that are associated with the drives should be suppressed with diodes or similar devices. The Allen-Bradley 1305 AC drives come with power ratings 0.37 to 4 kilowatts at a power rating of 380 to 460 Volts AC. The devices support the use of the RFI filters that are used for controlling the radio-frequency conducted emissions. Note that the manufacturer advises that cabling and installation guidelines be strictly adhered to to prevent the occurrence of EMI noise. However, it is recommended that an RFI filter be used wherever there is a likelihood of sensitive devices or circuits being installed on the same AC power supply.

The ambient operating temperature of the 1305 AC drives is 50 degrees Celsius maximum. Therefore, the users should ensure that the proper temperature is maintained when operating the unit. Otherwise, there is a risk of the drives not achieving optimal performance. During the installation of the drives, proper wiring is essential. There are various cable types that can be used for drive installation. For 1305 AC drive installation, use the unshielded cable, but ensure that it is separated from any nearby sensitive circuits. If there are a lot of sensitive circuits nearby, only use the shielded cable. Ensure that the shield is connected to the drive ground and the motor frame ground. Connections should be made at both ends to ensure minimal external magnetic fields.