1398-DDM-075

Available Now
Request a Quote

The Allen-Bradley 1398-DDM-075 has a 141-339 Volts DC Bus Voltage, a 47-63 Hz AC Input Frequency, and a 100-240V AC Auxiliary Input-Voltage. It also contains a 14.2 x 5.97 x 8.84 in (360.6 x 151.7 x 224.5 mm) Dimensions and a 30 amps rms AC Input Current.

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 1398-DDM-075.
Exchange: Exchange credit for your defective unit available.

To speak to a sales representative for pricing & lead time:

phone

International
919-205-4392
Rated 4.1 with 8 reviews
top legal disclaimer
top legal disclaimer

credit cards accepted
better business bureau

1398-DDM-075

Description: The Allen-Bradley 1398-DDM-075 has a 141-339 Volts DC Bus Voltage, a 47-63 Hz AC Input Frequency, and a 100-240V AC Auxiliary Input-Voltage. It also contains a 14.2 x 5.97 x 8.84 in (360.6 x 151.7 x 224.5 mm) Dimensions and a 30 amps rms AC Input Current.
Available Now
Request a quote for 1398-DDM-075

Warranty: 1 year DO Supply Warranty Included
Shipping: Worldwide shipping via DHL, UPS, Fedex, and TNT
Repairs: We offer repair service for the 1398-DDM-075.
Exchange: Exchange credit for your defective unit available.

To speak to a sales representative for pricing & lead time:

phone

International
919-205-4392

Rated 4.1 with 8 reviews

    Technical Specifications for 1398-DDM-075

ManufacturerRockwell Automation
BrandAllen-Bradley
Weight21.32 lbs (9.67 kg)
Output Peak Current50 amps (Single Phase); 75 amps (Three Phase)
Bus Voltage141-339 Volts DC
AC Input Frequency47-63 Hz
Dimensions14.2 x 5.97 x 8.84 in (360.6 x 151.7 x 224.5 mm)
AC Input Current30 amps rms
Auxiliary Input-Voltage100-240V AC
Address Switch16-Position Rotary DIP
Peak Power Output240 Volts rms 14 kWatts (Single Phase)
Continuous Power Output120 Volts rms 3.5 kWatts; 240 Volts rms 7.5 kWatts (Three Phase)
AC Input Voltage100-240 Volts rms Nominal (Single or Three Phase)
AC Input CurrentTorque or Velocity
Operating Temperature0 to 55 degrees Celsius
Product LineULTRA 200 Series
Part Number/Catalog No. 1398-DDM-075
UPC662453565323
ManufacturerRockwell Automation
BrandAllen-Bradley
Weight21.32 lbs (9.67 kg)
Output Peak Current50 amps (Single Phase); 75 amps (Three Phase)
Bus Voltage141-339 Volts DC
AC Input Frequency47-63 Hz
Dimensions14.2 x 5.97 x 8.84 in (360.6 x 151.7 x 224.5 mm)
AC Input Current30 amps rms
Auxiliary Input-Voltage100-240V AC
Address Switch16-Position Rotary DIP
Peak Power Output240 Volts rms 14 kWatts (Single Phase)
Continuous Power Output120 Volts rms 3.5 kWatts; 240 Volts rms 7.5 kWatts (Three Phase)
AC Input Voltage100-240 Volts rms Nominal (Single or Three Phase)
AC Input CurrentTorque or Velocity
Operating Temperature0 to 55 degrees Celsius
Product LineULTRA 200 Series
Part Number/Catalog No. 1398-DDM-075
UPC662453565323

About 1398-DDM-075

The Allen-Bradley 1398-DDM-075 ULTRA 200 ™ Servo Drive is included in the 1398 ULTRA ™ Series. This module is equipped with 2 analog inputs to limit the number of external currents and with 2 analog outputs for monitoring the currently operating variables and torque dividers. There are 3 connectors in this module: the serial connector, the control and feedback connector, and the power connector. Two user-programmable and an output voltage of approximately 10V is the analog output of this module. The 1398-DDM-075 module also features an analog output with a resolution of 8 bits and 12 bits. The analog input voltage ranges from 0-10 volts. The analog input uses 10-bit resolution. The 1398-DDM-075 has an integral supply and a shunt regulator, and it uses microcontrollers to manage a machine’s position, velocity, and current.


The 1398-DDM-075 Servo Drive has great functionality and requires minimal maintenance. When maintenance is needed, the standard procedure is to check the whether the cable insulation and the connections are still good. The recommended moisture limit between 5 and 95%, the same as the other ULTRA 200 drives. The weight of the 1398-DDM-075 is 21.32 lbs. The peak output current for single-phase power and the peak output current for 3-phase power are 50A and 75A, respectively. The input frequency is 47-63 Hz. When operating the 1398-DDM-075 ULTRA 200 ™ servo drive with single-phase power, the current limit must be set properly to avoid damage to the module.

FAQ for 1398-DDM-075

QuestionAnswer
1: What current limits parameters must be set for a single-phase 1398-DDM-075? The current limits of a single-phase 1398-DDM-075 must be set as follows: Positive Current Limit- 50 A peak. Negative Current Limit- 50A peak. Average Current: 15 A continuous. Please note that failing to set these parameters can cause drive malfunction and/or potential damage.
2: What kind of memory does 1398-DDM-075 have? 1398-DDM-075 has 128kB of EPROM Flash Memory and 34kB of RAM.
3: Does 1398-DDM-075 have motor overload protection? Yes, 1398-DDM-075 motor overload protection engages within 8 minutes of operation at 200% overload and within 20 seconds of operation at 600% overload.

Repair Services for 1398-DDM-075

Type Lead Time Price Action
Repair Service 2-4 weeks $2634.14cartAdd to Cart

Our highly skilled technicians can repair your 1398-DDM-075. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions for 1398-DDM-075

Please refer to the manual for more information about the 1398-DDM-075 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
1398-DDM-075 Ser A
1398-DDM-075/A, Series A, Rev A Request Quote
1398-DDM-075 Ser B
1398-DDM-075/B, Series B, Rev B Request Quote
1398-DDM-075 Ser C
1398-DDM-075/C, Series C, Rev C Request Quote
1398-DDM-075 Ser D
1398-DDM-075/D, Series D, Rev D Request Quote
1398-DDM-075 Ser E
1398-DDM-075/E, Series E, Rev E Request Quote
1398-DDM-075 Ser F
1398-DDM-075/F, Series F, Rev F Request Quote
1398-DDM-075 Ser G
1398-DDM-075/G, Series G, Rev G Request Quote
1398-DDM-075 Ser H
1398-DDM-075/H, Series H, Rev H Request Quote
1398-DDM-075 Ser I
1398-DDM-075/I, Series I, Rev I Request Quote
1398-DDM-075 Ser J
1398-DDM-075/J, Series J, Rev J Request Quote
Common misspellings:
  • l398-DDM-075
  • 139b-DDM-075
  • 1398-DDM-o75
  • 1398DDM075

Dimensions For 1398-DDM-075

Size
Input Type
Panel Cutout Height in mm
Panel Cutout Width in mm
Terminal Height in mm
Terminal Width in mm
Terminal Overall Depth in mm
Terminal Mounted Depth in mm

Dimensions For 1398-DDM-075

Resolutions For 1398-DDM-075

Technical Specifications
ManufacturerRockwell Automation
BrandAllen-Bradley
Weight21.32 lbs (9.67 kg)
Output Peak Current50 amps (Single Phase); 75 amps (Three Phase)
Bus Voltage141-339 Volts DC
AC Input Frequency47-63 Hz
Dimensions14.2 x 5.97 x 8.84 in (360.6 x 151.7 x 224.5 mm)
AC Input Current30 amps rms
Auxiliary Input-Voltage100-240V AC
Address Switch16-Position Rotary DIP
Peak Power Output240 Volts rms 14 kWatts (Single Phase)
Continuous Power Output120 Volts rms 3.5 kWatts; 240 Volts rms 7.5 kWatts (Three Phase)
AC Input Voltage100-240 Volts rms Nominal (Single or Three Phase)
AC Input CurrentTorque or Velocity
Operating Temperature0 to 55 degrees Celsius
Product LineULTRA 200 Series
Part Number/Catalog No. 1398-DDM-075
UPC662453565323
ManufacturerRockwell Automation
BrandAllen-Bradley
Weight21.32 lbs (9.67 kg)
Output Peak Current50 amps (Single Phase); 75 amps (Three Phase)
Bus Voltage141-339 Volts DC
AC Input Frequency47-63 Hz
Dimensions14.2 x 5.97 x 8.84 in (360.6 x 151.7 x 224.5 mm)
AC Input Current30 amps rms
Auxiliary Input-Voltage100-240V AC
Address Switch16-Position Rotary DIP
Peak Power Output240 Volts rms 14 kWatts (Single Phase)
Continuous Power Output120 Volts rms 3.5 kWatts; 240 Volts rms 7.5 kWatts (Three Phase)
AC Input Voltage100-240 Volts rms Nominal (Single or Three Phase)
AC Input CurrentTorque or Velocity
Operating Temperature0 to 55 degrees Celsius
Product LineULTRA 200 Series
Part Number/Catalog No. 1398-DDM-075
UPC662453565323
About

The Allen-Bradley 1398-DDM-075 ULTRA 200 ™ Servo Drive is included in the 1398 ULTRA ™ Series. This module is equipped with 2 analog inputs to limit the number of external currents and with 2 analog outputs for monitoring the currently operating variables and torque dividers. There are 3 connectors in this module: the serial connector, the control and feedback connector, and the power connector. Two user-programmable and an output voltage of approximately 10V is the analog output of this module. The 1398-DDM-075 module also features an analog output with a resolution of 8 bits and 12 bits. The analog input voltage ranges from 0-10 volts. The analog input uses 10-bit resolution. The 1398-DDM-075 has an integral supply and a shunt regulator, and it uses microcontrollers to manage a machine’s position, velocity, and current.


The 1398-DDM-075 Servo Drive has great functionality and requires minimal maintenance. When maintenance is needed, the standard procedure is to check the whether the cable insulation and the connections are still good. The recommended moisture limit between 5 and 95%, the same as the other ULTRA 200 drives. The weight of the 1398-DDM-075 is 21.32 lbs. The peak output current for single-phase power and the peak output current for 3-phase power are 50A and 75A, respectively. The input frequency is 47-63 Hz. When operating the 1398-DDM-075 ULTRA 200 ™ servo drive with single-phase power, the current limit must be set properly to avoid damage to the module.

FAQ

Question: What current limits parameters must be set for a single-phase 1398-DDM-075?
Answer: The current limits of a single-phase 1398-DDM-075 must be set as follows: Positive Current Limit- 50 A peak. Negative Current Limit- 50A peak. Average Current: 15 A continuous. Please note that failing to set these parameters can cause drive malfunction and/or potential damage.

Question: What kind of memory does 1398-DDM-075 have?
Answer: 1398-DDM-075 has 128kB of EPROM Flash Memory and 34kB of RAM.

Question: Does 1398-DDM-075 have motor overload protection?
Answer: Yes, 1398-DDM-075 motor overload protection engages within 8 minutes of operation at 200% overload and within 20 seconds of operation at 600% overload.

Repairs
Type Lead Time Price Action
Repair Service 2-4 weeks $2634.14cartAdd to Cart

Our highly skilled technicians can repair your 1398-DDM-075. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Type Lead Time Price Action
Repair Service 2-4 weeks $2634.14cartAdd to Cart

Our highly skilled technicians can repair your 1398-DDM-075. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.

Revisions

Please refer to the manual for more information about the 1398-DDM-075 such as the wiring diagrams, data sheets, firmware information and migration or obsolescence details.

Revision Part # Also Known as Availability
1398-DDM-075 Ser A
1398-DDM-075/A, Series A, Rev A Request Quote
1398-DDM-075 Ser B
1398-DDM-075/B, Series B, Rev B Request Quote
1398-DDM-075 Ser C
1398-DDM-075/C, Series C, Rev C Request Quote
1398-DDM-075 Ser D
1398-DDM-075/D, Series D, Rev D Request Quote
1398-DDM-075 Ser E
1398-DDM-075/E, Series E, Rev E Request Quote
1398-DDM-075 Ser F
1398-DDM-075/F, Series F, Rev F Request Quote
1398-DDM-075 Ser G
1398-DDM-075/G, Series G, Rev G Request Quote
1398-DDM-075 Ser H
1398-DDM-075/H, Series H, Rev H Request Quote
1398-DDM-075 Ser I
1398-DDM-075/I, Series I, Rev I Request Quote
1398-DDM-075 Ser J
1398-DDM-075/J, Series J, Rev J Request Quote

Common misspellings:
  • l398-DDM-075
  • 139b-DDM-075
  • 1398-DDM-o75
  • 1398DDM075
PDF