| Manufacturer | Allen Bradley |
|---|---|
| Category | Drives |
| Product Line | Servo Drive 1398 |
| Part Number | 19101-660 |
| Weight | 75.00 lbs (34.02 kg) |
| Operating Temperature | 32-104 F (0-40 C) |
| Shock | 15 g 11 ms half sine |
| Vibration | 2 g from 10?2000 Hz |
| Output Peak Current | 7.5 amps |
| Bus Voltage | 141-339 Volts (DC) |
| AC Input Current | 5 amps rms |
| AC Input Frequency | 47-63 Hz |
The Allen-Bradley 19101-660 is an active shunt regulator that can be used with various ULTRA series drives, specifically the ULTRA3000, ULTRA5000, and ULTRA 100 drives, as they do not come with internal shunt circuitry that prevents overvoltage faults due to undissipated excess energy. It is capable of monitoring the drive’s DC bus voltage and if the voltage of the drive reaches the activation level, this shunt regulator will drop the DC bus voltage, dissipating the excess energy as heat. Note that the amount of average power that can be dissipated on a drive is dependent on the ambient temperature. This 300 W shunt regulator has peak shunting and continuous shunt capabilities, with the peak shunting a result of using a shunt resistor of 36 Ω and the continuous shunt is dependent on the peak power level, shunt time, and cycle time. When installing the 19101-660 shunt regulator, it is vital that it only be placed in an upright position and that there are no temperature-sensitive components placed above.
Previously known as the 1398-SR3AF shunt regulator, the 19101-660 has a bus voltage that ranges from 141 to 339V DC, as well as an output peak current of 7.5 A. The AC input current of the 19101-660 shunt regulator is 5 A RMS and its AC input frequency is 47 to 63 Hz. It also has a peak operating vibration of 2 g at 10 to 2000 Hz and a shock of 15 g for 11 ms (half-sine). Weighing 1.51 kg or 3.34 lbs., this shunt regulator has approximate dimensions of 2.5 x 5.6 x 7.8 inches.