The Allen-Bradley 40382-811-03 controller is a motor controller and it is intended for most general applications, with an input power rating of 100 to 240V AC and a small margin of error (-15 to +10%). It is reliable and can control external devices with current ranging from 97 to 1000 Amps.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Motor Controller |
| Product Line | SMC Dialog Plus |
| Part Number | 40382-811-03 |
| Weight | 12.00 lbs (5.44 kg) |
| Input Power | 100 to 240V |
| Frequency | 50/60 Hz |
| Terminals | 11 and 12 |
| Line Voltage | 200 to 480V |
| SMC Rating | 720 Amps |
| Overload Class | Off, 10, 15, 20, 30 |
| Motor FLC | 1 to 999.9 Amps |
| Stall Protection and Jam Detection | 0.0 to 10.0 seconds |
The 40382-811-03 controller is a controller that is manufactured by Allen-Bradley/Rockwell Automation. The controller has a control input power of 100 to 240 Volts AC (-15 to +10%) 1-phase, at 50 to 60 Hertz, 24 Volts AC (-15 to +10%) 1-phase at 50 to 60 Hertz, and 24 Volts DC (-20 to +10%) 1-phase. Control power is connected to the controller at Terminals 11 and 12. The control power required by the controller is 40 Volt-Amps. For controllers rated at 97 to 1000 Amps, control power is also required for the heatsink fans. Depending on the specific application, additional control circuit transformer VA capacity may be required. If the control power input is rated at 100 to 240 Volts AC, the controller microprocessor will self-adjust to the input control voltage level.
The Allen-Bradley 40382-811-03 controller comes with a selectable kick start and this feature provides a boost which breaks away loads that require a pulse of high torque to get started. This is intended to provide a pulse of current that is 55 percent of the full load current. The 40382-811-03 controller also has a dual ramp start that is essential for applications with varying loads. The users can program the allowed number of starts per hour at up to 99 starts to help eliminate motor stress that is often caused by starting over repeatedly within a short time. This SMC dialog plus controller monitors other devices by using internal thermistors when the power pole’s maximum rated temperature is reached. The current sensing capability of the The 40382-811-03 SMC controller is disabled during bypass operation.