Description: The 150-F43NBDB is a Smart Motor Controller from the SMC Flex product family that is manufactured by Allen-Bradley. Typically termed as motor soft-starter, this solid-state device has an operating at an input voltage of 200-460VAC, 3-Phase, 50/60Hz. This controller is operable with line-connected and Delta Connected motors. With line-connected motors, it has an output power range of 10 - 30 HP @ 60 Hz; 11 - 22 kW @ 50 Hz, and an output current range of 12-60 Amperes. For Delta-connected motors, it has an output power range of 20 - 50 HP @ 60 Hz; 22 - 37 kW @ 50 Hz, and an output current range of 14.9 - 74 Amperes. This controller is configurable to implement Soft Start, Kickstart, Current Limit, Pump, Control, Dual ramp start, Full Voltage Start, Coast, Soft Stop, and Smart Motor Braking with a built-in Pump Control feature.
Preowned
Includes a 1-Year DO Supply warranty.
DO Supply is not an authorized distributor for Allen Bradley.
Warranty: | 1 year DO Supply Warranty Included |
Shipping: | Worldwide shipping via DHL, UPS, Fedex, and TNT |
Repairs: | We offer repair service for the 150-F43NBDB. |
Exchange: | Exchange credit for your defective unit available. |
Conditions: | We sell preowned surplus and refurbished parts. |
Manufacturer | Rockwell Automation |
Input Line Voltage | 200-460 VAC |
Enclosure Type | Open |
Part Number/Catalog No. | 150-F43NBDB |
Control Voltage | 100-240 VAC |
Brand | Allen-Bradley |
Product Series | SMC Flex |
Product Description | Smart Motor Controller (SMC) |
Input frequency | 50 / 60 Hz |
Output Current | 43 A |
Output Power | 30 HP |
Supported functions | Soft Start; Selectable kickstart; Current limit start; Dual ramp start, Full Voltage start, Preset Low Speed, Cost-to-rest; Soft Stop and Smart Motor Braking |
Optional functions | Pump control |
Mounting | Panel Mount |
Compatible motor | standard squirrel-cage induction motor or a Wye-Delta, six-lead motor |
Metering function | included |
Manufacturer: | Rockwell Automation |
Operating Modes: | Soft Start, Kickstart, Current Limit, Pump, Control, Dual ramp start, Full Voltage Start, Coast, Soft Stop and Smart Motor Braking. |
Product Line | SMC-Flex |
Brand: | Allen-Bradley |
Kickstart adjustments: | 0, 0.5, 1.0, or 1.5 s @ 450% Full Load Current (FLA) |
Bulletin Number | Solid State Controller |
Product Family: | SMC Flex Smart Motor Controller |
Start-time adjustments: | 2, 5, 10, 15, 20, 25, or 30 s |
Bulletin Number: | 150 |
Current Limit: | 150%, 250%, 350%, and 450% of full load current |
Controller Rating | 480A, 400 HP at 460V AC |
Catalog number: | 150-F43NBDB |
Line Voltage: | 208…460V AC, 3-Phase,47 and 63 Hz |
Operating Modes: | Soft-start, Linear Acceleration/Deceleration, Current Limit, Dual Ramp Start, Full Voltage, Soft Stop, Preset Slow Speed |
Output current | 12-60 Amperes for line-connected motors; 14.9 - 74 Amperes for Delta connected motors |
Optional control mode: | Pump Control |
Output Power | 10 - 30 HP @ 60 Hz; 11 - 22 kW @ 50 Hz for line-connected motors; 20 - 50 HP @ 60 Hz; 22 - 37 kW @ 50 Hz for Delta connected motors |
Rated Voltage | 500/575V AC |
Applicable Motor Type | Standard squirrel-cage induction motor or a Wye- Delta, six-lead motor |
Output contacts | One (1) Normally Open (N.O.); One (1) Normally Closed (N.C.) contacts |
Control Option | Pump |
Line Voltage: | 200…460V AC, 3-Phase, 50 and 60 Hz |
Alarm Contact assignments | Overload, underload, undervoltage, overvoltage, unbalance, jam, stall, and ground fault |
Control Voltage: | 100-1240 VAC |
Selectable Overload Trip Class | Trip Class 10, 15, or 20 |
Output Current range: | Line-Connected Motors: 8.6-43 Amperes Delta Connected Motors: 14.9-74 Amperes |
Metering | Amps, volts, kW, kWh, MW, MWH, elapsed time, power factor, and motor thermal capacity usage. |
Output power range: | Line Connected motors: 10-30 HP; 11-22 kW Delta connected motors: 22-37 kW; 20-50 Hp |
Built-in status indicator | Stopped, starting, stopping, at speed, alarm, and fault. |
Auxiliary Contacts | Four (4) Fully-programmable contacts |
Mounting: | Panel Mount |
Human Interface Module | Integrated |
Communication ports | One (1) DPI for optional HMI; One (1) DPI for expansion module |
Metering | Amps, volts, kW, kWh, MW, MWH, elapsed time, power factor, motor thermal capacity usage |
Status Indication | Stopped, starting, stopping, at speed, alarm, and fault. |
Protection and Diagnostics | Power loss, line fault, voltage unbalance, excessive starts/hour, phase reversal, undervoltage, overvoltage, controller temp, stall, jam, open gate, overload, underload, communication fault. |
Manufacturer | Rockwell Automation |
Input Line Voltage | 200-460 VAC |
Enclosure Type | Open |
Part Number/Catalog No. | 150-F43NBDB |
Control Voltage | 100-240 VAC |
Brand | Allen-Bradley |
Product Series | SMC Flex |
Product Description | Smart Motor Controller (SMC) |
Input frequency | 50 / 60 Hz |
Output Current | 43 A |
Output Power | 30 HP |
Supported functions | Soft Start; Selectable kickstart; Current limit start; Dual ramp start, Full Voltage start, Preset Low Speed, Cost-to-rest; Soft Stop and Smart Motor Braking |
Optional functions | Pump control |
Mounting | Panel Mount |
Compatible motor | standard squirrel-cage induction motor or a Wye-Delta, six-lead motor |
Metering function | included |
Manufacturer: | Rockwell Automation |
Operating Modes: | Soft Start, Kickstart, Current Limit, Pump, Control, Dual ramp start, Full Voltage Start, Coast, Soft Stop and Smart Motor Braking. |
Product Line | SMC-Flex |
Brand: | Allen-Bradley |
Kickstart adjustments: | 0, 0.5, 1.0, or 1.5 s @ 450% Full Load Current (FLA) |
Bulletin Number | Solid State Controller |
Product Family: | SMC Flex Smart Motor Controller |
Start-time adjustments: | 2, 5, 10, 15, 20, 25, or 30 s |
Bulletin Number: | 150 |
Current Limit: | 150%, 250%, 350%, and 450% of full load current |
Controller Rating | 480A, 400 HP at 460V AC |
Catalog number: | 150-F43NBDB |
Line Voltage: | 208…460V AC, 3-Phase,47 and 63 Hz |
Operating Modes: | Soft-start, Linear Acceleration/Deceleration, Current Limit, Dual Ramp Start, Full Voltage, Soft Stop, Preset Slow Speed |
Output current | 12-60 Amperes for line-connected motors; 14.9 - 74 Amperes for Delta connected motors |
Optional control mode: | Pump Control |
Output Power | 10 - 30 HP @ 60 Hz; 11 - 22 kW @ 50 Hz for line-connected motors; 20 - 50 HP @ 60 Hz; 22 - 37 kW @ 50 Hz for Delta connected motors |
Rated Voltage | 500/575V AC |
Applicable Motor Type | Standard squirrel-cage induction motor or a Wye- Delta, six-lead motor |
Output contacts | One (1) Normally Open (N.O.); One (1) Normally Closed (N.C.) contacts |
Control Option | Pump |
Line Voltage: | 200…460V AC, 3-Phase, 50 and 60 Hz |
Alarm Contact assignments | Overload, underload, undervoltage, overvoltage, unbalance, jam, stall, and ground fault |
Control Voltage: | 100-1240 VAC |
Selectable Overload Trip Class | Trip Class 10, 15, or 20 |
Output Current range: | Line-Connected Motors: 8.6-43 Amperes Delta Connected Motors: 14.9-74 Amperes |
Metering | Amps, volts, kW, kWh, MW, MWH, elapsed time, power factor, and motor thermal capacity usage. |
Output power range: | Line Connected motors: 10-30 HP; 11-22 kW Delta connected motors: 22-37 kW; 20-50 Hp |
Built-in status indicator | Stopped, starting, stopping, at speed, alarm, and fault. |
Auxiliary Contacts | Four (4) Fully-programmable contacts |
Mounting: | Panel Mount |
Human Interface Module | Integrated |
Communication ports | One (1) DPI for optional HMI; One (1) DPI for expansion module |
Metering | Amps, volts, kW, kWh, MW, MWH, elapsed time, power factor, motor thermal capacity usage |
Status Indication | Stopped, starting, stopping, at speed, alarm, and fault. |
Protection and Diagnostics | Power loss, line fault, voltage unbalance, excessive starts/hour, phase reversal, undervoltage, overvoltage, controller temp, stall, jam, open gate, overload, underload, communication fault. |
The 150-F43NBDB is part of Allen-Bradley’s Smart Motor Controller (SMC) series. It is specifically an SMC Flex motor controller, more commonly known as a soft-starter device, providing a safe and efficient method of starting and stopping a Squirrel cage of Delta-connected Six-lead AC motor. It also helps to prolong the operation of the connected AC operator, minimizing the mechanical, electrical, and thermal stress brought by sudden starting, stopping, or change of motor rotation direction. The 150-F43NBDB is a panel-mounted device. It must be mounted within an enclosure that offers protection against corrosive gasses and vapors, water, airborne contaminants, and metal filings. The minimum enclosure size that the 150-F43NBDB requires is 406 mm (16 inches) for height; 305 mm (12 inches) for width and 203 inches (8 mm) for Depth. The 150-F43NBDB comes with standard starting and stopping functions such as Soft Start, Kickstart, Current Limit, Pump, Control, Dual ramp start, Full Voltage Start, Coast, Soft Stop, and Smart Motor Braking. Additionally, this controller is added with a built-in Pump Control feature. Aside from these control methods, this controller also supports a metering function where totalizing of Amps, Volts, kW, kWh, MW, MWH, elapsed time, power factor, motor thermal capacity usage can be calculated for metering and consumption monitoring requirements. This smart motor controller is powered by an input voltage range of 200-460VAC, 3-Phase, 50/60Hz and delivers varying output ratings such as output power range of 10 - 30 HP @ 60 Hz; 11 - 22 kW @ 50 Hz and output current range of 12-60 Amperes for Line-connected motors and 20 - 50 HP @ 60 Hz; 22 - 37 kW @ 50 Hz and output current range of 14.9 - 74 Amperes for Delta connected motors.
The Allen-Bradley 150-F43NBDB is a soft-starter, solid-state controller that belongs the Bulletin 150 - SMC Flex series. The supply voltage rating for this controller is 200 to 460 Volts AC, 50 and 60 Hertz and has a current rating of 43 Amps, 30 Horsepower. It also comes with a pump control variant and motor control protection. The control voltage for this module ranges from 100 Volts AC (minimum) to 240 Volts AC (maximum). The 150-F43NBDB is a low-voltage, soft-starter that comes with an internal bypass contact that helps to minimize heat generation. This feature reduces both the enclosure size and total costs. Because of its built-in current and voltage protection, the 150-F43NBDB provides diagnostic capability and power monitoring enhancement. For ease of maintenance, this controller also offers product modularity. Another great feature of this product is its integrated multilingual, backlit LCD. It is helpful for monitoring and programming as well as process optimization and setup efficiency. It has a standard line and load termination feature too.
The 150-F43NBDB is a 3-phase controller housed in an open-type enclosure. It also comes with the optional pump control feature that offers a built-in, anti-backspin timer. Because it belongs to the SMC-Flex series, the 150-F43NBDB incorporates electronic motor overload protection as a standard feature. This protection is electronically achieved with an I2t algorithm. Like other Bulletin 150 - SMC Flex Smart Motor Controllers, the 150-F43NBDB features an Integrated DPI Communication Feature, Metering, 4 Fully Programmable Auxiliary Contacts, Stall Protection and Jam Detection, Voltage Unbalance Protection, Network I/O, and Ground Fault, Tachometer, and PTC Inputs. The Allen-Bradley 150-F43NBDB is a Smart Motor Control from the SMC Flex series. This controller, is used to control the starting and stopping characteristics of a 3-Phase AC motor via variety of configurable functions such as Soft Start, Full Voltage Start, Smart Motor Braking, Current Limit Start, Dual Ramp Start, Accu-Stop, Selectable Kickstart, Pump Start, Slow Speed with Braking, Coast-to-rest, Preset Slow Speed, Linear Speed Acceleration (Tachometer required), and Soft Stop. Additionally, the 150-F43NBDB is provided with the Pump Stop feature which is practically used to prevent fluid surges. The 150-F43NBDB is provided with an integrated Liquid Crystal Display (LCD) and embedded keypad for local configuration and operation. It may also be configured using the Parameter Configuration Module, DriveExplorer and DriveExecutive software as well as the Connected Components Workbench (CCW). AN optional Human Interface Module (HIM) may also be installed to the controller’s internal Drive Peripheral Interface (DPI) for a more user-friendly local interface. Aside from being an electronic component mainly installed with Solid State components, the highly programmable and configurable environment of this device is powered by the built-in microprocessor. This controller has an applicable motor output current rating of 43 Amperes and 30 Horsepower. It accepts an input line voltage of 300 Horsepower at an input line voltage of 200-460 Volts AC, 3-Phase, along a frequency of 50 / 60 Hertz. It has a control voltage of 100-240 Volts AC. This controller can be specifically used with standard squirrel-cage induction motor or with a Wye-Delta Six-Lead motor. It has an open-type enclosure and supports panel mounting.
What are the starting and stopping modes supported by this motor controller?
The 150-F43NBDB is capable of Soft Start; Selectable kickstart; Current limit start; Dual ramp start, Full Voltage start, Preset Low Speed, Cost-to-rest; Soft Stop and Smart Motor Braking.
Does the 150-F43NBDB come with an optional function installed?
Yes. It comes with the optional Pump control function installed.
Does the 150-F43NBDB comes with an integrated Human Interface Module (HIM)?
No. The HIM for this device is optionally available.
1. What is the optional control feature of the 150-F43NBDB?
The 150-F43NBDB is provided with pump control feature.
2. What are the protection and diagnostic feature of the 150-F43NBDB?
The 150-F43NBDB has Power loss, line fault, voltage unbalance, excessive starts/hour, phase reversal, undervoltage, overvoltage, controller temp, stall, jam, open gate, overload, underload, communication fault.
3. What are the status indication provided by the 50-F43NBDB?
The 150-F43NBDB has Stopped, starting, stopping, at speed, alarm, and fault indications.
1. Does the 150-F43NBDB come with relay contact output?
Yes. The 150-F43NBDB comes with normally open (N.O.) contact outputs
2. What are the assignable parameters to the N.O. contact outputs?
Assignable parameters are Overload, underload, undervoltage, overvoltage, unbalance, jam, stall, and ground fault.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 150-F43NBDB. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Please refer to the manual for more information about the 150-F43NBDB such as the wiring diagrams, data sheets and migration or obsolescence details.
Revision Part # | Also Known as | Availability |
150-F43NBDB Ser A
|
150-F43NBDB/A, Series A, Rev A | Request Quote |
150-F43NBDB Ser B
|
150-F43NBDB/B, Series B, Rev B | Request Quote |
"The 150-F43NBDB is an SMF Flex Smart Motor Controller (SMC). The SMC Flex series, including the 150-F43NBDB are far more advanced soft-starter devices as it is capable of implementing a wider variety of functions such as Soft Start; Selectable kickstart; Current limit start; Dual ramp start, Full Voltage start, Preset Low Speed, Cost-to-rest; Soft Stop and Smart Motor Braking. Additionally, the 150-F43NBDB is also capable of Pump Control function which is used to prevent surges. " -DO Supply Tech
"The Allen-Bradley 150-F43NBDB is a Smart Motor Controller (SMC) from the SMC Flex product series. Compared to the 150-F43NBD which only has standard configuration, the 150-F43NBDB features an added Pump control capability which is useful in limiting fluid surges and limiting process connection rattling. Being part of the SMC Flex product family, it has more starting and Stopping modes compared to the SMC-3 product family. " -DO Supply Tech
"The 150-F43NBDB is a Smart Motor Controller (SMC) from Allen-Bradley. This motor controller comes with an integrated option control capability specifically, Pump Control. Compared to the 150-F43NBDB with standard configuration, the added Pump Control capability of the 150-F43NBDB makes this controller especially compatible for use in pump applications. " -DO Supply Tech
Size | |
Input Type | |
Panel Cutout Height | in mm |
Panel Cutout Width | in mm |
Terminal Height | in mm |
Terminal Width | in mm |
Terminal Overall Depth | in mm |
Terminal Mounted Depth | in mm |
Width | 5.91 in. (150.1 mm) |
Height | 12.09 in. (307 mm) |
Depth | 8.00 in. (203.1 mm) |
Approx Ship. Wt. | 12.6 lb (5.7 kg) |
Manufacturer | Rockwell Automation |
Input Line Voltage | 200-460 VAC |
Enclosure Type | Open |
Part Number/Catalog No. | 150-F43NBDB |
Control Voltage | 100-240 VAC |
Brand | Allen-Bradley |
Product Series | SMC Flex |
Product Description | Smart Motor Controller (SMC) |
Input frequency | 50 / 60 Hz |
Output Current | 43 A |
Output Power | 30 HP |
Supported functions | Soft Start; Selectable kickstart; Current limit start; Dual ramp start, Full Voltage start, Preset Low Speed, Cost-to-rest; Soft Stop and Smart Motor Braking |
Optional functions | Pump control |
Mounting | Panel Mount |
Compatible motor | standard squirrel-cage induction motor or a Wye-Delta, six-lead motor |
Metering function | included |
Manufacturer: | Rockwell Automation |
Operating Modes: | Soft Start, Kickstart, Current Limit, Pump, Control, Dual ramp start, Full Voltage Start, Coast, Soft Stop and Smart Motor Braking. |
Product Line | SMC-Flex |
Brand: | Allen-Bradley |
Kickstart adjustments: | 0, 0.5, 1.0, or 1.5 s @ 450% Full Load Current (FLA) |
Bulletin Number | Solid State Controller |
Product Family: | SMC Flex Smart Motor Controller |
Start-time adjustments: | 2, 5, 10, 15, 20, 25, or 30 s |
Bulletin Number: | 150 |
Current Limit: | 150%, 250%, 350%, and 450% of full load current |
Controller Rating | 480A, 400 HP at 460V AC |
Catalog number: | 150-F43NBDB |
Line Voltage: | 208…460V AC, 3-Phase,47 and 63 Hz |
Operating Modes: | Soft-start, Linear Acceleration/Deceleration, Current Limit, Dual Ramp Start, Full Voltage, Soft Stop, Preset Slow Speed |
Output current | 12-60 Amperes for line-connected motors; 14.9 - 74 Amperes for Delta connected motors |
Optional control mode: | Pump Control |
Output Power | 10 - 30 HP @ 60 Hz; 11 - 22 kW @ 50 Hz for line-connected motors; 20 - 50 HP @ 60 Hz; 22 - 37 kW @ 50 Hz for Delta connected motors |
Rated Voltage | 500/575V AC |
Applicable Motor Type | Standard squirrel-cage induction motor or a Wye- Delta, six-lead motor |
Output contacts | One (1) Normally Open (N.O.); One (1) Normally Closed (N.C.) contacts |
Control Option | Pump |
Line Voltage: | 200…460V AC, 3-Phase, 50 and 60 Hz |
Alarm Contact assignments | Overload, underload, undervoltage, overvoltage, unbalance, jam, stall, and ground fault |
Control Voltage: | 100-1240 VAC |
Selectable Overload Trip Class | Trip Class 10, 15, or 20 |
Output Current range: | Line-Connected Motors: 8.6-43 Amperes Delta Connected Motors: 14.9-74 Amperes |
Metering | Amps, volts, kW, kWh, MW, MWH, elapsed time, power factor, and motor thermal capacity usage. |
Output power range: | Line Connected motors: 10-30 HP; 11-22 kW Delta connected motors: 22-37 kW; 20-50 Hp |
Built-in status indicator | Stopped, starting, stopping, at speed, alarm, and fault. |
Auxiliary Contacts | Four (4) Fully-programmable contacts |
Mounting: | Panel Mount |
Human Interface Module | Integrated |
Communication ports | One (1) DPI for optional HMI; One (1) DPI for expansion module |
Metering | Amps, volts, kW, kWh, MW, MWH, elapsed time, power factor, motor thermal capacity usage |
Status Indication | Stopped, starting, stopping, at speed, alarm, and fault. |
Protection and Diagnostics | Power loss, line fault, voltage unbalance, excessive starts/hour, phase reversal, undervoltage, overvoltage, controller temp, stall, jam, open gate, overload, underload, communication fault. |
Manufacturer | Rockwell Automation |
Input Line Voltage | 200-460 VAC |
Enclosure Type | Open |
Part Number/Catalog No. | 150-F43NBDB |
Control Voltage | 100-240 VAC |
Brand | Allen-Bradley |
Product Series | SMC Flex |
Product Description | Smart Motor Controller (SMC) |
Input frequency | 50 / 60 Hz |
Output Current | 43 A |
Output Power | 30 HP |
Supported functions | Soft Start; Selectable kickstart; Current limit start; Dual ramp start, Full Voltage start, Preset Low Speed, Cost-to-rest; Soft Stop and Smart Motor Braking |
Optional functions | Pump control |
Mounting | Panel Mount |
Compatible motor | standard squirrel-cage induction motor or a Wye-Delta, six-lead motor |
Metering function | included |
Manufacturer: | Rockwell Automation |
Operating Modes: | Soft Start, Kickstart, Current Limit, Pump, Control, Dual ramp start, Full Voltage Start, Coast, Soft Stop and Smart Motor Braking. |
Product Line | SMC-Flex |
Brand: | Allen-Bradley |
Kickstart adjustments: | 0, 0.5, 1.0, or 1.5 s @ 450% Full Load Current (FLA) |
Bulletin Number | Solid State Controller |
Product Family: | SMC Flex Smart Motor Controller |
Start-time adjustments: | 2, 5, 10, 15, 20, 25, or 30 s |
Bulletin Number: | 150 |
Current Limit: | 150%, 250%, 350%, and 450% of full load current |
Controller Rating | 480A, 400 HP at 460V AC |
Catalog number: | 150-F43NBDB |
Line Voltage: | 208…460V AC, 3-Phase,47 and 63 Hz |
Operating Modes: | Soft-start, Linear Acceleration/Deceleration, Current Limit, Dual Ramp Start, Full Voltage, Soft Stop, Preset Slow Speed |
Output current | 12-60 Amperes for line-connected motors; 14.9 - 74 Amperes for Delta connected motors |
Optional control mode: | Pump Control |
Output Power | 10 - 30 HP @ 60 Hz; 11 - 22 kW @ 50 Hz for line-connected motors; 20 - 50 HP @ 60 Hz; 22 - 37 kW @ 50 Hz for Delta connected motors |
Rated Voltage | 500/575V AC |
Applicable Motor Type | Standard squirrel-cage induction motor or a Wye- Delta, six-lead motor |
Output contacts | One (1) Normally Open (N.O.); One (1) Normally Closed (N.C.) contacts |
Control Option | Pump |
Line Voltage: | 200…460V AC, 3-Phase, 50 and 60 Hz |
Alarm Contact assignments | Overload, underload, undervoltage, overvoltage, unbalance, jam, stall, and ground fault |
Control Voltage: | 100-1240 VAC |
Selectable Overload Trip Class | Trip Class 10, 15, or 20 |
Output Current range: | Line-Connected Motors: 8.6-43 Amperes Delta Connected Motors: 14.9-74 Amperes |
Metering | Amps, volts, kW, kWh, MW, MWH, elapsed time, power factor, and motor thermal capacity usage. |
Output power range: | Line Connected motors: 10-30 HP; 11-22 kW Delta connected motors: 22-37 kW; 20-50 Hp |
Built-in status indicator | Stopped, starting, stopping, at speed, alarm, and fault. |
Auxiliary Contacts | Four (4) Fully-programmable contacts |
Mounting: | Panel Mount |
Human Interface Module | Integrated |
Communication ports | One (1) DPI for optional HMI; One (1) DPI for expansion module |
Metering | Amps, volts, kW, kWh, MW, MWH, elapsed time, power factor, motor thermal capacity usage |
Status Indication | Stopped, starting, stopping, at speed, alarm, and fault. |
Protection and Diagnostics | Power loss, line fault, voltage unbalance, excessive starts/hour, phase reversal, undervoltage, overvoltage, controller temp, stall, jam, open gate, overload, underload, communication fault. |
The 150-F43NBDB is part of Allen-Bradley’s Smart Motor Controller (SMC) series. It is specifically an SMC Flex motor controller, more commonly known as a soft-starter device, providing a safe and efficient method of starting and stopping a Squirrel cage of Delta-connected Six-lead AC motor. It also helps to prolong the operation of the connected AC operator, minimizing the mechanical, electrical, and thermal stress brought by sudden starting, stopping, or change of motor rotation direction. The 150-F43NBDB is a panel-mounted device. It must be mounted within an enclosure that offers protection against corrosive gasses and vapors, water, airborne contaminants, and metal filings. The minimum enclosure size that the 150-F43NBDB requires is 406 mm (16 inches) for height; 305 mm (12 inches) for width and 203 inches (8 mm) for Depth. The 150-F43NBDB comes with standard starting and stopping functions such as Soft Start, Kickstart, Current Limit, Pump, Control, Dual ramp start, Full Voltage Start, Coast, Soft Stop, and Smart Motor Braking. Additionally, this controller is added with a built-in Pump Control feature. Aside from these control methods, this controller also supports a metering function where totalizing of Amps, Volts, kW, kWh, MW, MWH, elapsed time, power factor, motor thermal capacity usage can be calculated for metering and consumption monitoring requirements. This smart motor controller is powered by an input voltage range of 200-460VAC, 3-Phase, 50/60Hz and delivers varying output ratings such as output power range of 10 - 30 HP @ 60 Hz; 11 - 22 kW @ 50 Hz and output current range of 12-60 Amperes for Line-connected motors and 20 - 50 HP @ 60 Hz; 22 - 37 kW @ 50 Hz and output current range of 14.9 - 74 Amperes for Delta connected motors.
The Allen-Bradley 150-F43NBDB is a soft-starter, solid-state controller that belongs the Bulletin 150 - SMC Flex series. The supply voltage rating for this controller is 200 to 460 Volts AC, 50 and 60 Hertz and has a current rating of 43 Amps, 30 Horsepower. It also comes with a pump control variant and motor control protection. The control voltage for this module ranges from 100 Volts AC (minimum) to 240 Volts AC (maximum). The 150-F43NBDB is a low-voltage, soft-starter that comes with an internal bypass contact that helps to minimize heat generation. This feature reduces both the enclosure size and total costs. Because of its built-in current and voltage protection, the 150-F43NBDB provides diagnostic capability and power monitoring enhancement. For ease of maintenance, this controller also offers product modularity. Another great feature of this product is its integrated multilingual, backlit LCD. It is helpful for monitoring and programming as well as process optimization and setup efficiency. It has a standard line and load termination feature too.
The 150-F43NBDB is a 3-phase controller housed in an open-type enclosure. It also comes with the optional pump control feature that offers a built-in, anti-backspin timer. Because it belongs to the SMC-Flex series, the 150-F43NBDB incorporates electronic motor overload protection as a standard feature. This protection is electronically achieved with an I2t algorithm. Like other Bulletin 150 - SMC Flex Smart Motor Controllers, the 150-F43NBDB features an Integrated DPI Communication Feature, Metering, 4 Fully Programmable Auxiliary Contacts, Stall Protection and Jam Detection, Voltage Unbalance Protection, Network I/O, and Ground Fault, Tachometer, and PTC Inputs. The Allen-Bradley 150-F43NBDB is a Smart Motor Control from the SMC Flex series. This controller, is used to control the starting and stopping characteristics of a 3-Phase AC motor via variety of configurable functions such as Soft Start, Full Voltage Start, Smart Motor Braking, Current Limit Start, Dual Ramp Start, Accu-Stop, Selectable Kickstart, Pump Start, Slow Speed with Braking, Coast-to-rest, Preset Slow Speed, Linear Speed Acceleration (Tachometer required), and Soft Stop. Additionally, the 150-F43NBDB is provided with the Pump Stop feature which is practically used to prevent fluid surges. The 150-F43NBDB is provided with an integrated Liquid Crystal Display (LCD) and embedded keypad for local configuration and operation. It may also be configured using the Parameter Configuration Module, DriveExplorer and DriveExecutive software as well as the Connected Components Workbench (CCW). AN optional Human Interface Module (HIM) may also be installed to the controller’s internal Drive Peripheral Interface (DPI) for a more user-friendly local interface. Aside from being an electronic component mainly installed with Solid State components, the highly programmable and configurable environment of this device is powered by the built-in microprocessor. This controller has an applicable motor output current rating of 43 Amperes and 30 Horsepower. It accepts an input line voltage of 300 Horsepower at an input line voltage of 200-460 Volts AC, 3-Phase, along a frequency of 50 / 60 Hertz. It has a control voltage of 100-240 Volts AC. This controller can be specifically used with standard squirrel-cage induction motor or with a Wye-Delta Six-Lead motor. It has an open-type enclosure and supports panel mounting.
What are the starting and stopping modes supported by this motor controller?
The 150-F43NBDB is capable of Soft Start; Selectable kickstart; Current limit start; Dual ramp start, Full Voltage start, Preset Low Speed, Cost-to-rest; Soft Stop and Smart Motor Braking.
Does the 150-F43NBDB come with an optional function installed?
Yes. It comes with the optional Pump control function installed.
Does the 150-F43NBDB comes with an integrated Human Interface Module (HIM)?
No. The HIM for this device is optionally available.
1. What is the optional control feature of the 150-F43NBDB?
The 150-F43NBDB is provided with pump control feature.
2. What are the protection and diagnostic feature of the 150-F43NBDB?
The 150-F43NBDB has Power loss, line fault, voltage unbalance, excessive starts/hour, phase reversal, undervoltage, overvoltage, controller temp, stall, jam, open gate, overload, underload, communication fault.
3. What are the status indication provided by the 50-F43NBDB?
The 150-F43NBDB has Stopped, starting, stopping, at speed, alarm, and fault indications.
1. Does the 150-F43NBDB come with relay contact output?
Yes. The 150-F43NBDB comes with normally open (N.O.) contact outputs
2. What are the assignable parameters to the N.O. contact outputs?
Assignable parameters are Overload, underload, undervoltage, overvoltage, unbalance, jam, stall, and ground fault.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 150-F43NBDB. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Type | Lead Time | Price | Action |
---|---|---|---|
Repair Service | 2-4 weeks | Ask | ![]() |
Our highly skilled technicians can repair your 150-F43NBDB. All of our repairs come with a 1 Year DO Supply Warranty. Please contact us for additional information about our repair process.
Please refer to the manual for more information about the 150-F43NBDB such as the wiring diagrams, data sheets and migration or obsolescence details.
Revision Part # | Also Known as | Availability |
150-F43NBDB Ser A
|
150-F43NBDB/A, Series A, Rev A | Request Quote |
150-F43NBDB Ser B
|
150-F43NBDB/B, Series B, Rev B | Request Quote |
Width | 5.91 in. (150.1 mm) |
Height | 12.09 in. (307 mm) |
Depth | 8.00 in. (203.1 mm) |
Approx Ship. Wt. | 12.6 lb (5.7 kg) |
"The 150-F43NBDB is an SMF Flex Smart Motor Controller (SMC). The SMC Flex series, including the 150-F43NBDB are far more advanced soft-starter devices as it is capable of implementing a wider variety of functions such as Soft Start; Selectable kickstart; Current limit start; Dual ramp start, Full Voltage start, Preset Low Speed, Cost-to-rest; Soft Stop and Smart Motor Braking. Additionally, the 150-F43NBDB is also capable of Pump Control function which is used to prevent surges. " -DO Supply Tech
"The Allen-Bradley 150-F43NBDB is a Smart Motor Controller (SMC) from the SMC Flex product series. Compared to the 150-F43NBD which only has standard configuration, the 150-F43NBDB features an added Pump control capability which is useful in limiting fluid surges and limiting process connection rattling. Being part of the SMC Flex product family, it has more starting and Stopping modes compared to the SMC-3 product family. " -DO Supply Tech
"The 150-F43NBDB is a Smart Motor Controller (SMC) from Allen-Bradley. This motor controller comes with an integrated option control capability specifically, Pump Control. Compared to the 150-F43NBDB with standard configuration, the added Pump Control capability of the 150-F43NBDB makes this controller especially compatible for use in pump applications. " -DO Supply Tech