Product image is representative; revision or series may vary. Contact us to request a specific version.
The 100S-D420EA22C contactor is a 3-pole Allen-Bradley safety contactor. The coil on the 100S-D420EA22C contactor is AC controlled. The rated coil voltage is 208 to 277 Volts AC.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Contactor |
| Product Line | 100 Contactors |
| Part Number | 100S-D420EA22C |
| UPC | 781180461330 |
| Weight | 0.25 lbs (0.11 kg) |
| Coil | Electronic |
| Coil Voltage | 208 to 277 Volts AC |
| PLC Interface | Yes |
| NC Contacts | 2 |
| NO Contacts | 2 |
| Operating Temperature | -25 to 60 degrees Celsius |
| Storage Temperature | -40 to 80 degrees Celsius |
| Altitude | 2000 meters |
| Isolation Voltage | 1000 Volts |
The Allen-Bradley 100S-D420EA22C contactor is a 3-pole AC operated contactor. Its electronic coil is rated for 208 to 277 Volts AC at 60 Hertz and at 50 Hertz. At 60 degrees Celsius, the operating current rating for the 100S-D420EA22C contactor is 420 Amps. At 40 degrees Celsius, the operating current rating of the 100S-D420EA22C contactor is 540 Amps. If the ambient temperature goes up to 70 degrees Celsius, the operating current will reduce to 85% of the rated current value for 60 degrees Celsius. Allen-Bradley recommends installing the 100S-D420EA22C contactor at altitudes of up to 6600 feet or 2000 meters above sea level. At higher altitudes, the contactor performance will derate from the standard rated values. The contactor also features a PLC interface.
The 100S-D420EA22C contactor is part of the 100S-D safety contactor product line from Allen-Bradley which features the mirror contact design. This design feature prevents state change on the normally closed auxiliary contacts when a power contact on the 100S-D420EA22C contactor welds. This safety feature on the contactor provides a reliable indication about the status of closed and open power poles on the 100S-D420EA22C contactor. Safety contactors from the 100S-D series are CE marked and are certified by the SUVA, CCC, and cULus (file E 41850) standards. They also comply with other standards including the CSA C22.2, IEC 6097-4-1, and IEC 60947 Type 2 standards. Allen-Bradley recommends that the users operating the contactor follow all of the operating and safety instructions provided in the product manual. To prevent electrical shock leading to injury, the power to the contactor should be disconnected prior to any maintenance activities.