The Allen-Bradley 140G-G2C3-C15 circuit breaker has been designed and manufactured as part of the Bulletin 104G MCB series of industrial circuit breakers. It is a molded case circuit breaker and a fixed thermal and fixed magnetic type of circuit breaker. The 140G-G2C3-C15 circuit breaker supports a current rating of 15 Amps, a thermal trip rating of 15 Amps, and a magnetic trip rating of 500 Amps. This circuit breaker also comes with 3 poles. The 140G-G2C3-C15 circuit breaker comes with end cap or bolt-on materials as a standard feature.
We sell industrial automation parts backed by our free 2-Year DO Supply Warranty.
Same-day domestic and fast international shipping with UPS, FedEx, DHL, and more.
AMEX, Visa, MasterCard, Discover, wire transfer, net terms, and more.
Repairs and exchanges are available for all automation products.
Drop shipping, blind shipping, and account shipping with no extra fees.
| Manufacturer | Allen Bradley |
|---|---|
| Product Type | Molded Case Circuit Breaker |
| Product Line | 140G MCB |
| Part Number | 140G-G2C3-C15 |
| UPC | 885630447049 |
| Weight | 2.81 lbs (1.28 kg) |
| Frame | G |
| Amps | 125 |
| Interrupting Rating | 25 kA |
| Protection Type | Fixed Thermal/ Fixed Magnetic |
| Current Range | 15 A |
| Rated Insulation Voltage | 800 V |
| Rated Impulse Withstand Voltage | 8 kV |
| Thermal Trip | 15 A |
| Magnetic Trip | 500 A |
The Allen-Bradley 140G-G2C3-C15 molded case circuit breaker is a thermal-magnetic circuit breaker from the 140G circuit breaker family designed to provide short-circuit protection for a wide variety of control panel applications. Like all 140G circuit breakers, the 140G-G2C3-C15 circuit breaker is sized according to the Table 430-152 of the NEC (National Electrical Code). The 140G-G2C3-C15 circuit breaker is suitable for branch circuits or main circuits with 600 Volts AC (690 Volts IEC) operating voltage. It has a breaking capacity value of 25 kiloamps (at 480 Volts AC), and a current rating of 125 Amps. The 140G-G2C3-C15 circuit breaker has a fixed thermal/magnetic trip unit with fixed thermal and magnetic trip ratings of 500 Amps and 15 Amps, respectively. The circuit breaker trips instantaneously when the current flowing through the circuit breaker exceeds the breaker’s set value.
The 140G-G2C3-C15 circuit breaker provides a thermal trip action by using its bimetallic element, which deflects when large currents flow through the circuit for long. It also provides magnetic trip action via an electromagnet coil that provides a magnetic field that is proportional to the applied current on the circuit, thus tripping when the current exceeds the set trip value. The 140G-G2C3-C15 circuit breaker has a lifespan rating of 25,000 operations (240 operations per hour), and an electrical lifespan of 8000 operations (120 operations per hour). It has 3-pole wiring with line and load side terminals. It is supplied with standard 1-meter pig-tail wiring terminals for installing internal accessories. The 140G-G2C3-C15 circuit breaker is mounted on a DIN rail, and it has an ingress protection rating of IP 20 or IP 40. The 140G-G2C3-C15 circuit breaker is calibrated for a 40 degrees Celsius ambient enclosure temperature, and it can be stored within a temperature range of -40 to 80 degrees Celsius. The 140G-G2C3-C15 circuit breaker weighs about 1.1 kilograms, and it has total dimensions of 76 x 70 x 130 millimeters.
| Revision Part # | Also known as | |
|---|---|---|
| 140G-G2C3-C15 Ser A | 140G-G2C3-C15/A, Series A, Rev A | |
| Don't see your particular revision? Contact us now. | ||
The Allen-Bradley 140G-G2C3-C15 Molded Case Circuit Breaker has a G Frame and 125 Amps. It also has a 25 kA Interrupting Rating and 3 Poles.